Baumer RR30.DAF0-GGPI.9VF/E029
Distance sensor

Baumer RR30.DAF0-GGPI.9VF/E029

art. 11220109

  • Small blind range 0.2 m
  • Push-pull and IO-Link outputs
  • Wide beam 12° opening angle
  • Suitable for structured surfaces (e.g. stones)
  • Ideal for level measurements in closed containers
Item Number: RR30.DAF0-GGPI.9VF/E029
1165.94
-
+
Total price: 1165.94
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Baumer Article no11220109
Scanning range Sd0.2 ... 6 m
Scanning range close limit Sdc0.2В ...В 6 m
Scanning range far limit Sde0.2 ... 6 m
VersionIO-Link dual channel
Repeat accuracy2 mm
Response time ton< 40 ms
Release time toff< 40 ms
Temperature drift<В± 10 mm (Full Scale)
Power-up driftCompensated after 20 min.
AdjustmentIO-Link
Light indicatorLED yellow
Power on indicationLED green
Carrier frequency122 ... 123 GHz
Band width1 GHz
Range resolution500 mm
Hysteresis typ.5 % Sde
Linearity errorВ± 10 mm
Modulation typeFMCW
Transmitting power (EIRP)< +20 dBm
Aperture angle12 В°
MTTF> 126 years
Approvals/certificatesEcolabFCC / CFR-47 part 15 (USA)RSS-210 Issue 10 (Canada)EN 305 550-1 V.1.2.1 (European Union)EN 305 550-2 V.1.2.1 (European Union)
Voltage supply range +Vs12 ... 30 VDC
Current consumption max. (no load)200 mA
Short circuit protectionYes
Reverse polarity protectionYes, Vs to GND
Output circuitIO-Link / push-pull
Output current< 100 mA< 50 mA (out 2)
Voltage drop Vd< 2.5 VDC
TypeCylindrical threaded
Housing materialStainless steel 1.4404 (V4A)
Width / diameter30 mm
Height / length97 mm
Connection typesConnector M12
Operating temperature-40В ...В +65 В°C
Storage temperature-40В ...В +85 В°C
Protection classIP 68/69K & proTect+
InterfaceIO-Link V1.1
Baud rate230,4 kBaud (COM 3)
Cycle time≥ 4 ms
Process data length208 Bit
Process data structureBit 0 = SSC1 (distance)Bit 1 = SSC2 (distance)Bit 2 = qualityBit 3 = alarmBit 5 = SSC4 (counter)Bit 8-15 = scale factorBit 16-47 = 32 Bit measurementBit 48-207 = 5 Peak (32 Bit Daten)
IO-Link port typeClass A
Additional dataDistanceExcess gainOperating cyclesOperating hoursBoot cyclesOperating voltageDevice temperatureHistogramsVelocity
Adjustable parametersSwitching pointSwitching hysteresisMeasured value filteringMeasuring rangeTime filtersOutput logicOutput circuitCounterAnalog output characteristicLED status indicatorsDeactivate the sensor elementFind Me functionSwitching window definitionSignal sensitivitySignal selection (1. / 2. / strongest / last)Tracking mode
Predefined preference profilesPrecise (standard)Fill level fluid (slow)Fill level fluid (fast)Fill level solidFast detectionTracking (slow)Tracking (standard)Tracking (fast)