Baumer RR30.DAO0-IGPI.9VF
Distance sensor

Baumer RR30.DAO0-IGPI.9VF

art. 11221321

  • Large measurement range up to 80 m via IO-Link
  • IO-Link and analog output (current 4...20 mA)
  • Narrow beam reduces false object detection
  • Suitable for distance measurement in outdoor areas
  • Ideal for measurements on corner cube
Item Number: RR30.DAO0-IGPI.9VF
1165.94
-
+
Total price: 1165.94
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Baumer Article no11221321
Scanning range Sd0.5 ... 60 m
Scanning range close limit Sdc0.5В ...В 60 m
Scanning range far limit Sde0.5 ... 60 m
Version2 outputs
Repeat accuracy1 mm
Response time ton< 80 ms
Release time toff< 80 ms
Temperature drift<В± 10 mm (Full Scale)
Power-up driftCompensated after 20 min.
AdjustmentIO-Link
Light indicatorLED yellow
Power on indicationLED green
Carrier frequency122 ... 123 GHz
Band width1 GHz
Range resolution500 mm
Hysteresis typ.2 % Sde
Linearity errorВ± 10 mm
Modulation typeFMCW
Transmitting power (EIRP)< +20 dBm
Aperture angle6 В°
MTTF> 126 years
Approvals/certificatesEcolabFCC / CFR-47 part 15 (USA)RSS-210 Issue 10 (Canada)EN 305 550-1 V.1.2.1 (European Union)EN 305 550-2 V.1.2.1 (European Union)
Voltage supply range +Vs12 ... 30 VDC
Current consumption max. (no load)220 mA
Short circuit protectionYes
Reverse polarity protectionYes, Vs to GND
Output circuitCurrent output / push-pull
Output signal4 ... 20 mA / 20 ... 4 mA
Output current< 100 mA
Switching outputPush-pull
Output functionNO / NC adjustable
Voltage drop Vd< 2.5 VDC
TypeCylindrical threaded
Housing materialStainless steel 1.4404 (V4A)
Width / diameter30 mm
Height / length107 mm
Connection typesConnector M12
Operating temperature-40В ...В +65 В°C
Storage temperature-40В ...В +85 В°C
Protection classIP 68/69K & proTect+
InterfaceIO-Link V1.1
Baud rate230,4 kBaud (COM 3)
Cycle time≥ 4 ms
Process data length208 Bit
Process data structureBit 0 = SSC1 (distance)Bit 1 = SSC2 (distance)Bit 2 = qualityBit 3 = alarmBit 5 = SSC4 (counter)Bit 8-15 = scale factorBit 16-47 = 32 Bit measurementBit 48-207 = 5 Peak (32 Bit Daten)
IO-Link port typeClass A
Additional dataDistanceExcess gainOperating cyclesOperating hoursBoot cyclesOperating voltageDevice temperatureHistogramsVelocity
Adjustable parametersSwitching pointSwitching hysteresisMeasured value filteringMeasuring rangeTime filtersOutput logicOutput circuitCounterAnalog output characteristicLED status indicatorsDeactivate the sensor elementFind Me functionSwitching window definitionSignal sensitivitySignal selection (1. / 2. / strongest / last)Tracking mode
Predefined preference profilesPrecise (standard)Fill level fluid (slow)Fill level fluid (fast)Fill level solidFast detectionTracking (slow)Tracking (standard)Tracking (fast)

Comments

No comments yet

Write a comment