Endress+Hauser Cerabar PMC51
Absolute and gauge pressure

Endress+Hauser Cerabar PMC51

Pressure transmitter

Accuracy

Standard 0.1%
Platinum 0.075%

Process temperature

-20В°C...125В°C
(-4В°F...275В°F)

Pressure measuring range

100 mbar...40 bar
(1.5psi...600psi)

Process pressure absolute / max. overpressure limit

60 bar (900 psi)

Main wetted parts

Ceraphire
Sealing
Alloy C276
316L

Max. measurement distance

400 m (1312 ft) H2O

Material process membrane

Ceramic

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)
relative/ absolute

Item Number: Cerabar PMC51
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Pressure Sensor  Cerabar M PMC51 is a digital transmitter. Feature of this series – oil-free ceramic membrane for measurements in liquids and gases.

Such devices have found application in absolutely all industries. The presence of a ceramic membrane provides a fairly high level of device security. Cerabar M  Vacuum resistant, with built-in damage detection system. A dedicated menu enables simple start-up and commissioning, which saves time and costs significantly.

Benefits:

  • Excellent for use in vacuum and for corrosive and abrasive service.
  • High safety provided by diaphragm failure detection.
  • Fracture-resistant ultra-pure ceramic diaphragm .
  • High resistance to condensation. This feature is suitable for hygienic applications.
  • Local display allows easy commissioning via menu, 4 … 20mA using FOUNDATION Fieldbus, HART, PROFIBUSPA protocols.
  • Able to measure the pressure value in systems yes SIL2, certified according to IEC 61511 and IEC 61508.
  • It has a modular concept for easy replacement of the electronic block or display.
  • Types of process attachment – hygienic, flanged, threaded.
  • Admissible temperature of the process itself – from -40°С - +130°С.
  • Measuring range – from -1/0mbar to + 40bar.
  • International certificates of explosion protection, SIL, WHG protection against overflow, hygienic certificates, marine certificates.

Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids.

Measuring principle

Absolute and gauge pressure

Characteristic

Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire)

Supply voltage

4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy

Standard 0.1%
Platinum 0.075%

Long term stability

0.2% of URL/ year
0.4% of URL/ 5 years
0.5% of URL/ 10 years

Process temperature

-40В°C...+130В°C
(-40В°F...+266В°F
+150В°C for 1h
(+302В°F for 1h)

Ambient temperature

-40В°C...+85В°C
(-40В°F...+185В°F)

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)
relative/ absolute

Smallest calibratable span

10 mbar (0.15 psi)

Vacuum resistance

0 mbar abs.

Max. Turn down

20:1

Max. overpressure limit

60 bar (900 psi)

Process connection

Thread:
G1/2...G2, R1/2, MNPT1/2
Flange:
DN25...DN80,
ASME 1"...4",
JIS 10K

Process connection hygienic

Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD

Material process membrane

Ceramic

Material gasket

Viton, EPDM, NBR, Kalrez

Fill fluid

None, dry measuring cell

Material housing

Die-cast aluminum,
AISI 316L

Communication

4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

SIL

Design approvals

EN10204-3.1
NACE MR0175

Hygienic approvals

CoC ASME-BPE
3A, EHEDG

Marine approvals

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

NSF

Successor

PMC51B

Measuring principle

Absolute and gauge pressure

Characteristic / Application

Smart and reliable pressure transmitter, with capacitive measuring cell and
ceramic process isolating diaphragm
(Ceraphire)

Supply / Communication

4 ..20 mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
PROFIBUS PA
FOUNDATION Fieldbus

Accuracy

Standard 0.1%
Platinum 0.075%

Long term stability

< 0,1% of URL/ year
< 0,25% of URL/ 5 years
< 0,4% of URL/ 10 years

Ambient temperature

-40В°C...85В°C
(-40В°F...185В°F)

Process temperature

-20В°C...125В°C
(-4В°F...275В°F)

Process pressure absolute / max. overpressure limit

60 bar (900 psi)

Pressure measuring range

100 mbar...40 bar
(1.5psi...600psi)

Main wetted parts

Ceraphire
Sealing
Alloy C276
316L

Process connection

Threads
Flanges (DIN, ASME, JIS)

Max. measurement distance

400 m (1312 ft) H2O

Communication

4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

SIL

Design approvals

EN 10204-3.1
NACE MR0175, MR0103

Hygienic approvals

3A, EHEDG
CoC ASME-BPE

Marine approval

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

NSF

Options

Local display

Successor

PMC51B

Application limits

Measuring cell: ceramics
If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure

Comments

No comments yet

Write a comment