Endress+Hauser Cerabar PMP51
Absolute and gauge pressure

Endress+Hauser Cerabar PMP51

Pressure transducer

Accuracy

Standard 0.1%
Platinum 0.075%

Process temperature

-40В°C...125В°C
(-40В°F...275В°F)

Pressure measuring range

1 bar...400 bar
(15 psi...6000 psi)

Process pressure absolute / max. overpressure limit

600 bar (9000 psi)

Main wetted parts

316L

Max. measurement distance

4000 m (13.123 ft) H2O

Material process membrane

316L, AlloyC,
Rhodium>Gold

Measuring cell

400mbar...400bar
(15psi...6000psi)
relative/ absolute

Item Number: Cerabar PMP51
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Cerabar M PMP51 is digital, has a metal membrane and is used in absolutely any industry for measuring mass, pressure, volume and level in liquids.

The device was developed to solve pressure measurement tasks up to 400bar. The device is equipped with a quick setup menu, which in turn has an adjustable measuring range.

Easy and quick commissioning, saving time and costs.

Main advantages of the pmp51 series:

  • Very accurate measurement of process values even when the process temperature changes.
  • High safety is ensured. This is achieved by a small flush process connection for hygienic type measurements.
  • Process pressure monitoring in systems up to SIL2, certified to IEC61508 and IEC61511 (GOSTR IEC61508 and GOSTR IEC61511).
  • Simple replacement of the electronics and display thanks to the modular concept.
  • Commissioning is quick and easy. Performed via local menu display, 4 ... 20mA using HART, PROFIBUSPA, FOUNDATION Fieldbus protocols.
  • System integration is simple and independent (HART/PA/FF).
  • Possible hygienic, threaded or flanged process connection.
  • Possess international certificates of explosion protection, overfill protection, hygienic certificates and marine certificates.
  • Admissible temperature of the process itself – from - 40°С - + 130°С.
  • Measuring range – from -1/0mbar to + 400bar.
  • International certificates of explosion protection, SIL, WHG protection against overflow, hygienic certificates, marine certificates.  

Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids.

Measuring principle

Absolute and gauge pressure

Characteristic / Application

Smart and reliable pressure transmitter, with piezoresistive measuring cell
and metal welded process isolating
diaphragm

Supply / Communication

4 ..20 mA HART:
11,5...45 V DC
Ex ia: 11,5...30 V DC
PROFIBUS PA
FOUNDATION Fieldbus

Accuracy

Standard 0.1%
Platinum 0.075%

Long term stability

< 0,1% von URL/ year
0,2% of URL/ 5 years
0,25% of URL/ 10 years

Ambient temperature

-40В°C...85В°C
(-40В°F...185В°F)

Process temperature

-40В°C...125В°C
(-40В°F...275В°F)

Process pressure absolute / max. overpressure limit

600 bar (9000 psi)

Pressure measuring range

1 bar...400 bar
(15 psi...6000 psi)

Main wetted parts

316L

Process connection

Threads
Flanges (DIN, ASME, JIS)
Hygienic connections
Tri-Clamp ISO2852

Max. measurement distance

4000 m (13.123 ft) H2O

Communication

4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

SIL

Design approvals

EN 10204-3.1
NACE MR0175, MR0103
AD2000

Hygienic approvals

3A, EHEDG
CoC ASME-BPE

Marine approval

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

NSF

Options

Local display

Successor

PMP51B

Application limits

Measuring cell: Metal welded
If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure

Measuring principle

Absolute and gauge pressure

Characteristic

Smart and reliable pressure transmitter, with piezoresistive measuring cell
and metal welded process isolating
diaphragm

Supply voltage

4...20mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy

Standard 0.1%
Platinum 0.075%

Long term stability

0.1% of URL/year
0.2% of URL/ 5 years
0.25% of URL/ 10 years

Process temperature

-40В°C...+130В°C
(-40В°F...+266В°F
+150В°C for 1h
(+302В°F for 1h)

Ambient temperature

-40В°C...+85В°C
(-40В°F...+185В°F)

Measuring cell

400mbar...400bar
(15psi...6000psi)
relative/ absolute

Smallest calibratable span

20 mbar (0.3 psi)

Vacuum resistance

10 mbar (0.15 psi)

Max. Turn down

20:1

Max. overpressure limit

600bar (9000psi)

Process connection

Thread:
G1/2...G2, MNPT1/2...MNPT2
Flange:
DN25...DN80,
ASME 1 1/2"...4",

Process connection hygienic

Tri-Clamp
DIN11851
NEUMO
Varivent N
SMS
DRD

Material process membrane

316L, AlloyC,
Rhodium>Gold

Material gasket

None, measuring cell welded

Fill fluid

Silicone oil,
Inert oil

Material housing

Die-cast aluminum,
AISI 316L

Communication

4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

SIL

Design approvals

EN10204-3.1
NACE MR0175

Hygienic approvals

3A, EHEDG
CoC ASME-BPE

Marine approvals

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

NSF

Successor

PMP51B

Comments

No comments yet

Write a comment