Endress+Hauser Cerabar PMC21
Absolute and gauge pressure

Endress+Hauser Cerabar PMC21

Pressure transducer

Accuracy

0.3 %

Process temperature

-25 В°...+100 В°C
(-13 В°F....+185 В°F)

Pressure measuring range

+100 mbar...+40 bar
(+1.5 psi...+600 psi)

Measuring cell

+100 mbar...+40 bar
(+1.5 psi...+600 psi)

Item Number: Cerabar PMC21
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Cerabar PMC21 ceramic diaphragm pressure transmitter. Very compact, suitable for measurements in gases and liquids.

Specifications:

  • Pressure measuring range: 20 mbar ... 40 bar.< /li>
  • Protection class: up to IP68.
  • Features abrasion-resistant Ceraphire membrane.
  • Body: 316L

Designed for application in all industries.

Cost-effective pressure transducer with ceramic sensor for measurement in gases or liquids.

Measuring principle

Absolute and gauge pressure

Characteristic / Application

Cost effective pressure transducer, capacitive sensor with ceramic measuring diaphragm

Supply / Communication

10...30 VDC

Accuracy

0.3 %

Long term stability

0.2 % of URL/year

Ambient temperature

-40 В°C...+85 В°C
(-40 В°F...+185 В°F)

Process temperature

-25 В°C...+100 В°C
(-13 В°F....+185 В°F)

Process pressure absolute / max. overpressure limit

max. 60 bar
(900 psi)

Pressure measuring range

+100 mbar...+40 bar
(+1.5 psi...+600 psi)

Process connection

Threads:
G1/4, G1/2,
MNPT 1/4, MNPT 1/2,
DIN13,
JIS R1/2

Communication

4...20 mA

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, NEPSI, EAC

Design approvals

EN 10204-3.1 Final inspection report
Cleaned from oil and grease
Cleaned for oxygen applications

Marine approval

RINA, KR

Measuring principle

Absolute and gauge pressure

Characteristic

Cost effective pressure transducer, capacitive sensor with ceramic measuring diaphragm

Supply voltage

10...30 VDC

Reference Accuracy

0.3 %

Long term stability

0.2 % of URL/year

Process temperature

-25 В°C...+100 В°C
(-13 В°F....+185 В°F)

Ambient temperature

-40 В°C...+85 В°C
(-40 В°F...+185 В°F)

Measuring cell

+100 mbar...+40 bar
(+1.5 psi...+600 psi)

Max. overpressure limit

max. 60 bar
(900 psi)

Process connection

Threads:
G1/4, G1/2,
MNPT 1/4, MNPT 1/2,
DIN13,
JIS R1/2

Communication

4...20 mA

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, NEPSI, EAC

Design approvals

EN 10204-3.1 Final inspection report
Cleaned from oil and grease
Cleaned for oxygen applications

Marine approvals

RINA, KR

Comments

No comments yet

Write a comment