Endress+Hauser Cerabar PMC51B
Pressure transmitter
Standard:
up to 0.075 %
Platinum:
up to 0.055 %
-40В°C...+100В°C
(-40В°F...+212В°F)
100 mbar...40 bar
(1.5 psi...600 psi)
Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez
Ceramic
Measuring cell100 mbar...40 bar
(1.5 psi...600 psi)
- Overview
- Comments
Smart transmitter with ceramic membrane for highly accurate measurement of liquids and gases.
Measuring principleAbsolute and gauge pressure
Characteristic / ApplicationPressure transmitter with ceramic process membran for accurate measurement in liquid or gases.
Intuitive and clear wizard for commissioning
BluetoothВ® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
Standard:
up to 0.075 %
Platinum:
up to 0.055 %
0.10 % of URL/ year
0.25 % of URL/ 5 years
0.40 % of URL/ 10 years
-40В°C...+85В°C
(-40В°F...+185В°F)
-40В°C...+100В°C
(-40В°F...+212В°F)
40 bar (600 psi)
Pressure measuring range100 mbar...40 bar
(1.5 psi...600 psi)
Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
400 m (1312 ft) H2O
Communication4...20 mA,
4...20 mA HART
ATEX, IEC Ex, CSA C/US, NEPSI
Safety approvalsSIL
Design approvalsEN 10204-3.1
NACE MR0175,
NACE MR0103
NSF, KTW
Application limitsMeasuring cell: ceramics
If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
Absolute and gauge pressure
CharacteristicPressure transmitter with ceramic process membran for accurate measurement in liquid or gases.
Intuitive and clear wizard for commissioning
Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Standard:
up to 0.075 %
Platinum:
up to 0.055 %
0.10% of URL/ year
0.25% of URL/ 5 years
0.40% of URL/ 10 years
-40В°C...+100В°C
(-40В°F...+212В°F)
-40В°C...+85В°C
(-40В°F...+185В°F)
100 mbar...40 bar
(1.5 psi...600 psi)
5 mbar (0.075 psi)
Vacuum resistanceup to 100В°C (212В°F)
Max. Turn down100:1
Max. overpressure limit60 bar (900 psi)
Process connectionThread:
G1/2...G2, R1/2, MNPT1/2...MNPT2,
FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Ceramic
Material gasketFKM, EPDM, HNBR, FFKM
Fill fluidnone, dry measuring cell
Material housingAluminium
Communication4...20 mA,
4...20 mA HART
ATEX, IEC Ex, CSA C/US, NEPSI
Safety approvalsSIL
Design approvalsEN10204-3.1
NACE MR0175,
NACE MR0103
NSF, KTW
SpecialitiesBluetoothВ® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Comments
No comments yet