Endress+Hauser Cerabar S PMC631
Pressure Sensor
- Overview
- Comments
Measuring principle
Absolute and gauge pressure
Characteristic
Digital pressure transmitter with diaphragm seal for hygienic applications
Safety by function monitoring, modular transmitter design
Supply voltage
4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
Ex d[ia]: 13...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Ex ia: 9...24V DC
Reference Accuracy
0.2%
Long term stability
0,1% of URL/year
Process temperature
-40В°C...350В°C
Ambient temperature
-40В°C...85В°C
Measuring cell
400mbar...40bar
Max. overpressure limit
60bar
Process connection
Hygienic connections
Clamp ISO2852
(Tri-Clamp compatible)
Communication
4..20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals
ATEX
FM
CSA
SIL
EN10204-3.1
Successor
For hygienic applications refer to Deltapilot S and Cerabar M. Clamp, DIN11851, DRD, ect within PMP75
Measuring principle
Absolute and gauge pressure
Characteristic / Application
Digital pressure transmitter with diaphragm seal for hygienic applications
Safety by function monitoring, modular transmitter design
Supply / Communication
4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
Ex d[ia]: 13...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Ex ia: 9...24V DC
Accuracy
0.2%
Long term stability
0,1% of URL/year
Ambient temperature
-40В°C...85В°C
Process temperature
-40В°C...350В°C
Process pressure absolute / max. overpressure limit
60bar
Pressure measuring range
400mbar...40bar
Main wetted parts
Ceraphire ceramic
Alloy C
316L
Tantal
PTFE-Foil
Process connection
Tri-Clamp
Hygienic connections
Max. measurement distance
400m H2O
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals
ATEX
FM
CSA
SIL
EN10204-3.1
Options
digital display
SS- or Aluminumhousing
Successor
For hygienic applications refer to Deltapilot S and Cerbar M. Clamp, DIN 11851,DRD,ect. within PMP75
Application limits
Changing density
Comments
No comments yet