Endress+Hauser Cleanfit CPA473
Manual or automatic retractable assembly

Endress+Hauser Cleanfit CPA473

Retractable assembly for measuring pH and ORP

Process temperature

PA pressure cylinder (manually only):
Max. 80 В°C (176 В°F)
Stainless steel pressure cylinder: up to 100В°C (212 В°F) with continuous operation up to 6 bar (87 psi)

Process pressure

PA pressure cylinder: Max. 6 bar (87 psi)
Stainless steel pressure cylinder: Max. 10 bar (145 psi)
Pneumatic outlet safety seal:
6 bar at 100 В°C (87 psi at 212 В°F)

Item Number: Cleanfit CPA473
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Retractable mortise fitting with stainless steel ball valve. Introduces pH and ORP electrodes into the process.

Assembly with ball valve for the chemical, paper, and wastewater industries.

Measuring principle

Potentiometric

Application

Chemical industry, paper industry, wastewater, industrial water, power plants, refuse incinerators, sugar industry

Installation

Retractable assembly with ball valve

Characteristic

Open and closed tank, piping (min DN80)

Design

Manual or pneumatical
Manual or pneumatical ball valve
Can be fully automated with CPC30 / 300
Integrated rinse chamber with connection G 1/4" or NPT 1/4"

Material

Seals: EPDM / FPM / perfluoroelastomer
Electrode holder: stainless steel 1.4404
Ball valve: Stainless steel 1.4401, PTFE
Inlet safety seal: PVDF, PTFE, VitonВ®
Outlet safety seal: PVDF, Stainless steel 1.4404
Rinse connection socket: Stainless steel 1.4404

Dimension

Immersion depth: 61 to 235mm
(2.4 inch to 9.25 inch)

Process temperature

PA pressure cylinder (manually only):
Max. 80 В°C (176 В°F)
Stainless steel pressure cylinder: up to 100В°C (212 В°F) with continuous operation up to 6 bar (87 psi)

Process pressure

PA pressure cylinder: Max. 6 bar (87 psi)
Stainless steel pressure cylinder: Max. 10 bar (145 psi)
Pneumatic outlet safety seal:
6 bar at 100 В°C (87 psi at 212 В°F)

Connection

G1Вј internal thread, DN50, DN65, ANSI 2"

Additional certifications

3.1. acc. to EN 10204

Measuring principle

Sensor ORP / Redox

Application

Chemical industry, paper industry, wastewater, industrial water, power plants, refuse incinerators, sugar industry

Installation

Retractable holder with ball valve

Characteristic

Open and closed tank, piping (min DN80)

Design

Manual or pneumatical
Manual or pneumatical ball valve
Can be fully automated with CPC30 / 300
Integrated rinse chamber with connection G 1/4" or NPT 1/4"

Material

Seals: EPDM / FPM / perfluoroelastomer
Electrode holder: stainless steel 1.4404
Ball valve: Stainless steel 1.4401, PTFE
Inlet safety seal: PVDF, PTFE, VitonВ®
Outlet safety seal: PVDF, Stainless steel 1.4404
Rinse connection socket: Stainless steel 1.4404

Dimension

Immersion depth: 61 to 235mm
(2.4 inch to 9.25 inch)

Process temperature

PA pressure cylinder (manually only):
Max. 80 В°C (176 В°F)
Stainless steel pressure cylinder:
up to 100В°C (212 В°F) with continuous operation up to 6 bar (87 psi)

Process pressure

PA pressure cylinder: Max. 6 bar (87 psi)
Stainless steel pressure cylinder: Max. 10 bar (145 psi)
Pneumatic outlet safety seal:
6 bar at 100 В°C (87 psi at 212 В°F)

Connection

G1Вј internal thread, DN50, DN65, ANSI 2"

Additional certifications

3.1.B EN 10204

Comments

No comments yet

Write a comment