Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3

Measuring range

0 to 1000 kg/h (0 to 37 lb/min)

Medium temperature range

50 to +200 В°C (58 to +392 В°F)

Max. process pressure

PN 40, Class 300, 10K, 400 bar (5800 psi)

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)

Item Number: Cubemass
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Compact sensor for smallest quantities with easy system integration.

Measuring principle

Coriolis

Product headline

Compact sensor for smallest quantities with easy system integration.
Measuring accurately smallest quantities of liquids and gases.

Sensor features

Space-saving installation compact single-tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Suitable for skids lightweight sensor.
Nominal diameter: DN 1 to 6 . Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 В°C (+392 В°F).

Transmitter features

Cost savings very low power consumption. Fast commissioning pre-configured devices. Automatic recovery of data for servicing.
Robust transmitter housing. Modbus RS485. Pulse output.

Nominal diameter range

DN 1 to 6

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3

Measuring range

0 to 1000 kg/h (0 to 37 lb/min)

Max. process pressure

PN 40, Class 300, 10K, 400 bar (5800 psi)

Medium temperature range

-50 to +200 В°C (-58 to +392 В°F)

Ambient temperature range

Standard: -20 to +60 В°C (-4 to +140 В°F)
Option: -40 to +60 В°C (-40 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

Powder...coated die...cast aluminium

Degree of protection

IP67, type 4X enclosure

Display/Operation

No local operation
Configuration via operating tools possible

Outputs

Pulse/frequency/switch output (passive), phase...shifted pulse

Inputs

None

Digital communication

Modbus RS485

Power supply

DC 10 to 30 V
AC 20 to 28 V

Hazardous area approvals

ATEX, IECEx, NEC/CEC, NEPSI

Other approvals and certificates

3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN