Endress+Hauser CYH101
Universal hanger for rebar
Universal hanger for rebar
- Overview +
- Comments +
Universal pendant mount for CYH101 pH/ORP, oxygen and conductivity sensor assemblies, as well as oxygen and turbidity sensors. With protective coating.
Measuring principleSingle beam scattered light
ApplicationSewage treatment, inflow and outflow. Activated sludge basin. Waste water treatment plants. Neutralisation basins.
InstallationThe universal suspension assembly holder CYH101 mounted on an upright post is designed for use in open channels, basins or tanks.
CharacteristicSimple and easy installation on basin rims. Flexible adaption to local mounting conditions due to various mounting options and adjustments. Easy rotation of the transverse pipe and altitude adjustment of the suspension chain permit optimal measuring point without interruption of operation. Pendulum motion promotes the sensor self-cleaning effect.
DesignThe CYH101 is intended to suspend CYA611, CPA111 and the CLA111.
The upright post is prepared for mounting of field transmitter.
Upright post : stainless steel AISI 304 Base plate, transverse pipe, immersion tube, weather protection cover : stainless steel AISI 304 Chain : PP
DimensionUpright post : 1495x60x60mm Base plate : 150x150mm Transverse pipe : 1490x30x30mm Immersion tube : 2000/3500 x40mm chain : 5000mm
Process temperature-15В°C - 80В°C
Process pressureAmbient pressure
Measuring principleTotal chlorine
Measuring principleAmperometric oxygen measurement
ApplicationSewage treatment, inflow and outflow. Activated sludge basin. Waste water treatment plants. Neutralisation basins.
InstallationThe universal suspension assembly holder CYH101 mounted on an upright post is designed for use in open channels, basins or tanks.
CharacteristicSimple and easy installation on basin rims. Flexible adaption to local mounting conditions due to various mounting options and adjustments. Easy rotation of the transverse pipe and altitude adjustment of the suspension chain permit optimal measuring point without interruption of operation. Pendulum motion promotes the sensor self-cleaning effect.
DesignThe CYH101 is intended to suspend CYA611, CPA111 and the CLA111.
The upright post is prepared for mounting of field transmitter.
Upright post : stainless steel AISI 304 Base plate, transverse pipe, immersion tube, weather protection cover : stainless steel
DimensionUpright post : 1495x60x60mm Base plate : 150x150mm Transverse pipe : 1490x30x30mm Immersion tube : 2000/3500 x40mm chain : 5000mm
Process temperature-15В°C - 80В°C
Process pressureAmbient pressure
Measuring principlePotentiometric
ApplicationSewage treatment, inflow and outflow.
Activated sludge basin.
Waste water treatment plants.
Neutralisation basins.
The universal suspension assembly holder CYH101 mounted on an upright post is designed for use in open channels, basins or tanks.
CharacteristicSimple and easy installation on basin rims.
Flexible adaption to local mounting conditions due to various mounting options and adjustments.
Easy rotation of the transverse pipe and altitude adjustment of the suspension chain permit optimal measuring point without interruption of operation.
Pendulum motion promotes the sensor self-cleaning effect.
The CYH101 is intended to suspend CYA611, CPA111 and the CLA111.
The upright post is prepared for mounting of field transmitter.
Upright post: stainless steel AISI 304
Base plate, transverse pipe, immersion tube, weather protection cover: stainless steel AISI 304Chain: PP
Upright post: 1495x60x60 mm
Base plate: 150x150 mm
Transverse pipe: 1490x30x30 mm
Immersion tube: 2000/3500 x40 mm
chain: 5000 mm
-15В°C - 80В°C
(5 - 176В°F)
Ambient pressure
Measuring principleConductive
ApplicationSewage treatment, inflow and outflow. Activated sludge basin. Waste water treatment plants. Neutralisation basins.
InstallationThe universal suspension assembly holder CYH101 mounted on an upright post is designed for use in open channels, basins or tanks.
CharacteristicSimple and easy installation on basin rims. Flexible adaption to local mounting conditions due to various mounting options and adjustments. Easy rotation of the transverse pipe and altitude adjustment of the suspension chain permit optimal measuring point without interruption of operation. Pendulum motion promotes the sensor self-cleaning effect.
DesignThe CYH101 is intended to suspend CYA611, CPA111 and the CLA111.
The upright post is prepared for mounting of field transmitter.
Upright post: stainless steel AISI 304 Base plate, transverse pipe, immersion tube, weather protection cover: stainless steel AISI 304 Chain: PP
DimensionUpright post: 1495x60x60 mm
(58.30x2.34x2.34 inch) Base plate: 150x150 mm
(5.85x5.85 inch) Transverse pipe: 1490x30x30mm Immersion tube : 2000/3500 x40mm chain : 5000mm
-15В°C - 80В°C