Endress+Hauser Deltabar PMD55
Differential pressure

Endress+Hauser Deltabar PMD55

Differential pressure sensor

Accuracy

0,1%
"PLATINUM" 0,075%

Max. measurement error

0,1%
"PLATINUM" 0,075%

Item Number: Deltabar PMD55
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The Deltabar PMD55 sensor from E+H is a differential pressure transmitter and is equipped with a welded metal diaphragm and a piezoresistive sensor.

The device is widely used in all areas of production in the field of continuous measurement of the value of the differential pressure in gases, steam and liquids.

The presence of a menu with the function of measuring range adjustment makes it possible to quickly perform commissioning, reduce costs and save time. SIL2 in accordance with IEC61508/IEC61511.

Main advantages and technical characteristics of Deltabar M:

  • Commissioning is carried out through the menu using PROFIBUSPA, FOUNDATION Fieldbus protocols , HART.
  • Easily switch between low and high pressure chambers via electronic switch.
  • Optimize spare parts stock and reduce costs through compact design and modularity.
  • <li >Availability of various certifications for almost all industries has made it possible to use these sensors all over the world.
  • Threaded process connection.
  • Temperature value: - 40 - + 85°C.
  • Pressure value: 0.5 -  40bar.
  • Error: 0.1%.
  • International certificates for use in hazardous areas.
  • Output signals: 4-20mA.    
  • Power supply: 11.5V-45V DC.

Differential pressure transmitter with metal sensor for measurement of pressure differences.

Process temperature

-40 В°C...85 В°C
(-40 В°F...185 В°F)

Medium temperature range

Temperature gradient from pressure piping

Pressure measuring range

10mbar...40bar
(0.15...580psi)

Process pressure absolute / max. overpressure limit

160 bar

Main wetted parts

316L

Max. process pressure

10 mbar...40 bar
(0.15...580 psi)

Material process membrane

316L, AlloyC,

Measuring cell

10 mbar...40 bar
(0.15...580 psi)

Measuring principle

Differential pressure

Product headline

Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability

Max. measurement error

0,1%
"PLATINUM" 0,075%

Max. process pressure

10 mbar...40 bar
(0.15...580 psi)

Medium temperature range

Temperature gradient from pressure piping

Display/Operation

Option

Outputs

4...20mA HART

Digital communication

HART

Hazardous area approvals

ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

Functional safety

SIL

Material certificates

NACE MR0103
NACE MR0175
EN10204-3.1

Measuring principle

Differential pressure

Product headline

Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability

Max. measurement error

0,1%
"PLATINUM" 0,075%

Max. process pressure

10mbar...40bar
(0.15...580psi)

Medium temperature range

Temperature gradient from pressure piping

Display/Operation

Option

Outputs

4...20mA HART

Digital communication

HART

Hazardous area approvals

ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

Functional safety

SIL

Material certificates

NACE MR0103
NACE MR0175
EN10204-3.1

Measuring principle

Differential pressure

Characteristic

Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability

Supply voltage

4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy

Standard 0.1%
Platinum 0.075%

Long term stability

0.05% of URL/ year
0.13% of URL/ 5 years
0.23% of URL/ 10 years

Process temperature

-40В°C...+85В°C
(-40В°F...+185В°F)

Ambient temperature

-40В°C...+85В°C
(-40В°F...+185В°F)

Measuring cell

10 mbar...40 bar
(0.15...580 psi)

Smallest calibratable span

10 mbar (0.15 psi)

Max. Turn down

20:1

Max. overpressure limit

on one side:
160 bar
(2300 psi)

Process connection

1/4-18 NPT

Material process membrane

316L, AlloyC,

Material gasket

Viton, PTFE, EPDM, NBR

Fill fluid

Silicone oil
Inert oil

Material housing

Die-cast aluminum

Communication

4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

SIL

Design approvals

NACE MR0175
EN10204-3.1

Successor

PMD55B

Measuring principle

Differential pressure

Product headline

Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability

Max. measurement error

0,1%
"PLATINUM" 0,075%

Max. process pressure

10mbar...40bar
(0.15...580psi)

Medium temperature range

Temperature gradient from pressure piping

Display/Operation

Option

Outputs

4...20mA HART

Digital communication

HART

Hazardous area approvals

ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

Functional safety

SIL

Material certificates

NACE MR0103
NACE MR0175
EN10204-3.1

Measuring principle

Differential pressure

Characteristic / Application

Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability

Supply / Communication

4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC

Accuracy

0,1%
"PLATINUM" 0,075%

Long term stability

0,05% of URL/year
0,125% of URL/5 years

Ambient temperature

-40В°C...85В°C
(-40В°F...185В°F)

Process temperature

-40 В°C...85 В°C
(-40 В°F...185 В°F)

Process pressure absolute / max. overpressure limit

160 bar

Pressure measuring range

10mbar...40bar
(0.15...580psi)

Main wetted parts

316L

Process connection

1/4-18 NPT

Communication

4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

SIL

Design approvals

EN 10204-3.1
NACE MR0175, MR0103
AD2000

Options

4-line digital display
Aluminium housing

Successor

PMD55B

Application limits

Measuring cell:
Metal welded

Comments

No comments yet

Write a comment