Endress+Hauser Deltabar PMD78B
Differential pressure transmitter

Endress+Hauser Deltabar PMD78B
Accuracy

Standard:
up to 0.1 %

Process temperature

-40В°C...+400В°C
(-40В°F...+752В°F)

Pressure measuring range

100 mbar...40 bar
(1.5psi...600 psi)

Main wetted parts

316L, AlloyC,
Tantal, Monel
PTFE, Gold

Material process membrane

316L, AlloyC,
Tantal,
Monel
PTFE
Gold

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)

Item Number: Deltabar PMD78B
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Minimizes ambient and process temperature effects on your measurement thanks to the TempC membrane.

Measuring principle

Differential pressure

Characteristic / Application

Smart differential pressure transmitter with one or two capillaries, full range of certifications and Heartbeat Technology.
Intuitive and clear wizards for commissioning, proof tests and verification.

Specialities

Heartbeat Technology,
BluetoothВ® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities
HistoROM

Supply / Communication

Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC

Accuracy

Standard:
up to 0.1 %

Long term stability

0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years

Ambient temperature

-54В°C...+85В°C
(-65В°F...+185В°F)

Process temperature

-40В°C...+400В°C
(-40В°F...+752В°F)

Process pressure absolute / max. overpressure limit

160 bar (2.400 psi)

Pressure measuring range

100 mbar...40 bar
(1.5psi...600 psi)

Main wetted parts

316L, AlloyC,
Tantal, Monel
PTFE, Gold

Process connection

Thread:
MNPT1/2, G1/2
Flange:
NPS 2"...4", DN50...100

Max. measurement distance

160 m (525 ft) H2O

Communication

4...20 mA HART

Certificates / Approvals

ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex

Safety approvals

SIL

Design approvals

EN 10204-3.1,
NACE MR0175,
NACE MR0103

Options

Touch control display

Application limits

Keine

Measuring principle

Differential pressure

Characteristic

Specialist with one or two capillaries for accurate differential pressure measurement.
Intuitive and clear wizards for commissioning, proof tests and verification.

Supply voltage

Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC

Reference Accuracy

Standard:
up to 0.1 %

Long term stability

0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years

Process temperature

-40В°C...+400В°C
(-40В°F...+752В°F)

Ambient temperature

-40В°C...+85В°C
(-40В°F...+185В°F)

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)

Smallest calibratable span

5 mbar (0.075 psi)

Vacuum resistance

50 mbar (0.73 psi)

Max. Turn down

100:1

Max. overpressure limit

160 bar
(2400 psi)

Process connection

Thread: MNPT1/2, G1/2
Flange: NPS 2"...4", DN50...100

Material process membrane

316L, AlloyC,
Tantal,
Monel
PTFE
Gold

Material gasket

PTFE, FKM,
EPDM, FFKM

Fill fluid

Silicone oil,
inert oil,
vegetable oil,
low- / high temperature oil

Material housing

Aluminium, 316L

Communication

4...20 mA HART

Certificates / Approvals

ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex

Safety approvals

SIL

Design approvals

EN10204-3.1,
NACE MR0175,
NACE MR0103

Specialities

Heartbeat Technology,
BluetoothВ® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM

Comments

No comments yet

Write a comment