Endress+Hauser Deltapilot FMB53
Hydrostatic Level measurement
Hydrostatic pressure sensor
AccuracyStandard 0.2%
Optional 0.1%
PE cable: -10В°...70В°C / 14В°F...158В°F
FEP cable: -10В°...80В°C / 14В°F...176В°F
100mbar...10bar
(1.5psi...150psi)
40 bar (600 psi)
Main wetted partsAlloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh
100 m (328 ft) H2O
Material process membrane316L, AlloyC,
Gold-Rhodium
PE, FEP
100 mbar...10 bar
(1.5 psi...150 psi)
- Overview
- Comments
Pressure transmitter for pressure measurement or hydrostatic level measurement, with flush mounted metal measuring cell CONTITE: - hermetically welded; - absolute resistance to condensation; - resistance to climatic influences; - long-term stability; - minimum temperature dependence. Rope version with suspension clamp
Pressure sensor with Contite measuring cell for hydrostatic level measurement.
Measuring principleHydrostatic
Characteristic / ApplicationPressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant and climatic-proofed
Cable version with suspension clamp
Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
diagnostic functions
Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Standard 0.2%
Optional 0.1%
0.05 % of URL/year
Ambient temperature-40В°C...85В°C
(-40В°F...185В°F)
PE cable: -10В°C...70В°C / 14В°F...158В°F
FEP cable: -10В°C...80В°C / 14В°F...176В°F
40 bar (600 psi)
Pressure measuring range100mbar...10bar
(1.5psi...150psi)
Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh
Mounting clamp
Max. measurement distance100 m (328 ft) H2O
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvalsSIL
Design approvalsEN10204-3.1
NACE MRO175
GL/ ABS/ LR/ BV/ DNV
Drinking water approvalsKTW/ NSF/ ACS
OptionsInitial device settings
Overvoltage protection
If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
Observe ratio head pressure : hydrostatic pressure
Hydrostatic pressure
CharacteristicPressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Cable version with suspension clamp
4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Standard 0.2%
Optional 0.1%
0.05 % of URL/year
Process temperaturePE cable: -10В°C...70В°C / 14В°F...158В°F
FEP cable: -10В°C...80В°C / 14В°F...176В°F
-40В°C...85В°C
(-40В°F...185В°F)
100 mbar...10 bar
(1.5 psi...150 psi)
10 mbar (1.45 psi)
Vacuum resistance0 mbar abs.
Max. Turn down100:1
Max. overpressure limit40 bar (600 psi)
Process connectionMounting clamp
Material process membrane316L, AlloyC,
Gold-Rhodium
PE, FEP
Viton, EPDM, Kalrez, none
Fill fluidInert oil,
Synthetic oil
316L, Die-cast aluminum
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvalsSIL
Design approvalsEN10204-3.1
NACE MR0175
GL/ ABS/ LR/ BV/ DNV
Drinking water approvalsKTW/ NSF/ ACS
SpecialitiesModularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions
Comments
No comments yet