Endress+Hauser Deltapilot FMB70
Hydrostatic Level measurement

Endress+Hauser Deltapilot FMB70
We ship to United States of America!

Hydrostatic pressure sensor

Accuracy

Standard 0.1%
Optional 0.075%

Process temperature

-10В°C...+100В°C
(+14В°F...+212В°F)

Pressure measuring range

100 mbar...10 bar
(1.5 psi...150 psi)

Process pressure absolute / max. overpressure limit

40 bar (600 psi)

Main wetted parts

Alloy C
316L

Max. measurement distance

100 m (328 ft) H2O

Material process membrane

316L, AlloyC,
Gold-Rhodium

Measuring cell

100 mbar...10 bar
(1.5 psi...150 psi)

Item Number: Deltapilot FMB70
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

Pressure transmitter for hydrostatic level measurement with CONTITE measuring cell and metal diaphragm.

Highest performance pressure sensor with the Contite cell for hydrostatic level measurement.

Measuring principle

Hydrostatic pressure

Characteristic

Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Compact version

Supply voltage

4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)

Reference Accuracy

Standard 0.1%
Optional 0.075%

Long term stability

0.05 % of URL/year

Process temperature

-10В°C...100В°C
(14В°F...212В°F)

Ambient temperature

-40В°C...85В°C
(-40В°F...185В°F)

Measuring cell

100 mbar...10 bar
(1.5 psi...150 psi)

Smallest calibratable span

25 mbar (3.63 psi)

Vacuum resistance

0 mbar abs.

Max. overpressure limit

40 bar (600 psi)

Process connection

Thread:
G1 1/2, MNPT1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K

Process connection hygienic

Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD

Material process membrane

316L, AlloyC,
Gold-Rhodium

Material gasket

None, measuring cell welded

Fill fluid

Inert oil,
Synthetic oil

Material housing

316L, Die-cast aluminum

Communication

4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

Safety approvals

SIL

Design approvals

EN10204-3.1
NACE MR0175
MR0103

Hygienic approvals

3A, EHEDG
CoC ASME-BPE

Marine approvals

GL, DNV

Drinking water approvals

NSF

Specialities

Gold-rhodium coated membrane

Measuring principle

Hydrostatic

Characteristic / Application

Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant and climatic-proofed

Specialities

Diagnostic functions

Supply / Communication

4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)

Accuracy

Standard 0.1%
Optional 0.075%

Long term stability

0.05 % of URL/year

Ambient temperature

-40В°C...+85В°C
(-40В°F...+185В°F)

Process temperature

-10В°C...+100В°C
(+14В°F...+212В°F)

Process pressure absolute / max. overpressure limit

40 bar (600 psi)

Pressure measuring range

100 mbar...10 bar
(1.5 psi...150 psi)

Main wetted parts

Alloy C
316L

Process connection

Thread:
G1 1/2, MNPT1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K

Process connection hygienic

Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD

Max. measurement distance

100 m (328 ft) H2O

Communication

4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

Safety approvals

SIL

Design approvals

EN10204-3.1
NACE MR0175, MR0103

Hygienic approvals

3A, EHEDG
CoC ASME-BPE

Marine approval

GL/ DNV

Drinking water approvals

NSF

Options

HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing

Application limits

Measuring cell: Contite,
condensate-proof, watertight,
metal welded
If pressurized, possibly use
differential pressure measurement
with two pressure
transmitters. Observe ratio
head pressure : hydrostatic
pressure


Buy Endress+Hauser Deltapilot FMB70 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade is a known electrical equipment supplier. We offer a wide range of electronic automation products. We ship to any location in the world. We can offer you competitive prices for all items from our web catalog and Eltra Trade is always on time with the delivery time. We have the best ratio of speed, product quality and price.

Comments

No comments yet