Endress+Hauser Memosens CPS96E
Digital combined pH/ORP sensor

Endress+Hauser Memosens CPS96E
Measurement range

ORP: 1 500 to 1 500 mV
pH: 0 to 14

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) absolute

Item Number: Memosens CPS96E
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Memosens 2.0 electrode for heavily polluted media in chemical processes, paper or paint production.

Measuring principle

Potentiometric

Application

pH / ORP sensor for heavily contaminated media
and suspended solids
Chemical processes
Pulp and paper industry
Flue gas cleaning
Contaminated media:
Solids
Emulsions
Precipitation reactions

Characteristic

Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications

Measurement range

ORP: 1 500 to 1 500 mV
pH: 0 to 14

Measuring principle

Pt-disc as additional ORP element
rH measurement and control of the reference impedance

Design

All shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel

Material

Sensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide

Dimension

Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch)

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) absolute

Temperature sensor

NTC 30k

Ex certification

With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2

Connection

Inductive, digital connection head with Memosens 2.0 technology

Ingres protection

IP68

Measuring principle

Sensor ORP / Redox

Application

pH / ORP sensor for heavily contaminated media
and suspended solids
Chemical processes
Pulp and paper industry
Flue gas cleaning
Contaminated media:
Solids
Emulsions
Precipitation reactions

Characteristic

Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications

Measurement range

ORP: 1 500 to 1 500 mV
pH: 0 to 14

Measuring principle

Pt-disc as additional ORP element
rH measurement and control of the reference impedance

Design

All shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel

Material

Sensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide

Dimension

Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch)

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) absolute

Temperature sensor

NTC 30k

Ex certification

With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2

Connection

Inductive, digital connection head with Memosens 2.0 technology

Ingres protection

IP68

Comments

No comments yet

Write a comment