Endress+Hauser Dosimag
Electromagnetic flowmeter

Endress+Hauser Dosimag
Max. measurement error

В±0.25 % o.r. В± 1 to 4 m/s (3.3 to 13 ft/s)
В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
В±5 % o.r.

Measuring range

0.14 to 1.66 l/s (0.035 to 0.44 gal/s)

Medium temperature range

Seal material EPDM: 20 to +130 В°C (4 to +266 В°F)
Seal material Silicone: 20 to +130 В°C (4 to +266 В°F)
Seal material Viton: 0 to +150 В°C (+32 to +302 В°F)

Max. process pressure

PN 16

Wetted materials

Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum

Item Number: Dosimag
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor.

Measuring principle

Electromagnetic

Product headline

Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor.
For demanding dosing and filling applications.

Sensor features

High process safety high measuring accuracy and repeatability in shortest filling time. Energy...saving flow measurement no pressure loss due to cross section constriction. Maintenance...free no moving parts.
Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (В№вЃ„в‚€ to 1"). Measuring device conform to FDA.

Transmitter features

Versatile and time-saving wiring plug connector. Industry-optimized ultra-compact design. For hygienic requirements stainless steel housing.
Pulse/frequency/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter.

Nominal diameter range

DN 4 (⁵⁄₃₂"), 8 (⁵⁄₁₆"), 15 (½"), 25 (1")

Wetted materials

Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum

Measured variables

Volume flow

Max. measurement error

В±0.25 % o.r. В± 1 to 4 m/s (3.3 to 13 ft/s)
В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
В±5 % o.r.

Measuring range

0.14 to 1.66 l/s (0.035 to 0.44 gal/s)

Max. process pressure

PN 16

Medium temperature range

Seal material EPDM: 20 to +130 В°C (4 to +266 В°F)
Seal material Silicone: 20 to +130 В°C (4 to +266 В°F)
Seal material Viton: 0 to +150 В°C (+32 to +302 В°F)

Ambient temperature range

40 to +60 В°C (40 to +140 В°F)

Sensor housing material

1.4308 (304)

Transmitter housing material

1.4308 (304)

Degree of protection

IP66/67, type 4X enclosure

Display/Operation

No local Operation
Configuration via operating tools possible

Outputs

Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

Modbus RS485

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus

Product safety

CE

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025)
NTEP

Material certificates

3.1 material

Hygienic approvals and certificates

Sanitary approval: 3-A, EHEDG, seals acc. to FDA (except EPDM)

Comments

No comments yet