Max. measurement error

Mass flow (liquid): В±0.15 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 18 000 kg/h (0 to 660 lb/min)

Medium temperature range

40 to +125 В°C (40 to +257 В°F)
150 В°C allowed for 1 h

Max. process pressure

PN 40

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Item Number: Dosimass
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The compact sensor with an ultra-compact transmitter.

Measuring principle

Coriolis

Product headline

The compact sensor with an ultra-compact transmitter.
Measurement of liquids with the most diverse properties in continuous process control & batching applications.

Sensor features

High process safety high measuring accuracy for different media in shortest filling time. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Nominal diameter: DN 8 to 25 (ВівЃ„в‚€ to 1"). Various hygienic process connections, 3-A conform. CIP, SIP cleanable sensor.

Transmitter features

Versatile and time-saving wiring plug connector. Fast commissioning pre-configured devices. Automatic recovery of data for servicing.
Robust, ultra...compact transmitter housing. Pulse/frequency/switch output, Modbus RS485. Excellent and easily cleanable transmitter.

Nominal diameter range

DN 8 to 25 (ВівЃ„в‚€ to 1")

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Measured variables

Mass flow, density, temperature, volume flow

Max. measurement error

Mass flow (liquid): В±0.15 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 18 000 kg/h (0 to 660 lb/min)

Max. process pressure

PN 40

Medium temperature range

40 to +125 В°C (40 to +257 В°F)
150 В°C allowed for 1 h

Ambient temperature range

20 to +60 В°C (4 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

1.4308 (304)

Degree of protection

IP67, type 4X enclosure

Display/Operation

No local operation
Configuration via operating tools possible

Outputs

Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

Modbus RS485

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus

Other approvals and certificates

3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
3-A

Product safety

CE