Endress+Hauser Silopilot FMM50
Electromechanical Level measurement
Accuracy
+/- 5 cm
Process temperature-20В°C ... +230В°C
(-4В°F ... 446В°F)
0.8 ... 3 bar
(11.6psi...43.5psi)
70m (230ft)
Main wetted partsAluminium, Steel, Stainless steel
- Overview
- Comments
For continuous level measurement even in high bulk solids silos or bins.
Measuring principleElectromechanical
Characteristic / ApplicationNot affected by characteristics of solid medium
Mesuring range: 70m
Switch to indicate need of maintenance (predictive maintenance)
Supply / Communication180 ... 253 V, 50/60 Hz
Accuracy+/- 5 cm
Ambient temperature-40В°C ... +70В°C
(-40В°F ... 158В°F)
-20В°C ... +230В°C
(-4В°F ... 446В°F)
0.8 ... 3 bar
(11.6psi...43.5psi)
Aluminium, Steel, Stainless steel
Process connectionFlange DN100 PN16 / 4"
Blocking distanceTop: 500 mm (20 ")
Max. measurement distance70m (230ft)
Communication0/4...20 mA
Certificates / ApprovalsATEX
Design approvalsEN10204-3.1
People also buy