Endress+Hauser Deltabar FMD71
Electronic differential pressure

Endress+Hauser Deltabar FMD71
Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Process temperature

25...+150В°C
(13...+302В°F)

Pressure measuring range

100mbar...40bar
(1.5psi...600psi)

Process pressure absolute / max. overpressure limit

60 bar (900 psi)

Material process membrane

Ceramic
316L, AlloyC

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)

Item Number: Deltabar FMD71
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter.

Measuring principle

Differential pressure

Characteristic / Application

Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.

Supply / Communication

4...20 mA HART:
12...45V DC
Exia: 12...30V DC

Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Long term stability

0.05% of URL/year of individual sensor

Ambient temperature

40...+80В°C
(40...+176В°F)

Process temperature

25...+150В°C
(13...+302В°F)

Process pressure absolute / max. overpressure limit

60 bar (900 psi)

Pressure measuring range

100mbar...40bar
(1.5psi...600psi)

Process connection

Threads
Flanges (DIN, ASME, JIS)

Process connection hygienic

DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent

Communication

4...20 mA HART

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, INMETRO

Design approvals

NACE MR0175
EN10204-3.1

Hygienic approvals

FDA
3A

Options

4-line digital display
SS- or Aluminium housing

Application limits

Use Software Applicator Sizing Electronic DP

Measuring principle

Differential pressure

Characteristic

Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.

Supply voltage

4...20 mA HART:
12...45V DC (Non Ex)
Ex ia: 12...30V DC

Reference Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Long term stability

0.05% of URL/year of individual sensor

Process temperature

25...+150В°C
(13...+302В°F)

Ambient temperature

40...+80В°C
(40...+176В°F)

Measuring cell

100 mbar...40 bar
(1.5 psi...600 psi)

Vacuum resistance

0 mbar

Max. Turn down

100 : 1

Max. overpressure limit

60 bar (900 psi)

Process connection

Threads
Flansch (DIN, ASME, JIS)

Process connection hygienic

DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent

Material process membrane

Ceramic
316L, AlloyC

Material gasket

Viton, Kalrez, EPDM, NBR, Silicone

Fill fluid

Silicone Oil

Material housing

Die-cast aluminum
Stainless steel

Communication

4...20 mA HART

Certificates / Approvals

ATEX, FM, CSA, IECEx, NEPSI, INMETRO

Design approvals

NACE MR0175,
EN10204-3.1,

Hygienic approvals

EHEDG,
3A

Comments

No comments yet

Write a comment