Endress+Hauser Deltabar FMD72
Electronic differential pressure

Endress+Hauser Deltabar FMD72
Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Process temperature

40...+125В°C
(40 ... +257В°F)

Pressure measuring range

400 mbar...10 bar
(6 psi...150 psi)

Process pressure absolute / max. overpressure limit

160 bar (2400 psi)

Main wetted parts

316L, Alloy C

Material process membrane

316L, AlloyC,

Measuring cell

400 mbar...10 bar
(6 psi...150psi)

Item Number: Deltabar FMD72
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Electronic differential pressure system utilizing two metal sensor modules and one transmitter.

Measuring principle

Differential pressure

Characteristic

Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

Supply voltage

4...20 mA HART:
12...45V DC (Non Ex)
Ex ia: 12...30V DC

Reference Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Long term stability

0.05% of URL/year of individual sensor

Process temperature

40...+125В°C
(40...+257В°F)

Ambient temperature

40...+80В°C
(40...+176В°F)

Measuring cell

400 mbar...10 bar
(6 psi...150psi)

Vacuum resistance

10 mbar (0.15 psi)

Max. overpressure limit

160 bar (2400 psi)

Process connection

Threads
Flange (DIN, ASME,JIS)

Process connection hygienic

DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent

Material process membrane

316L, AlloyC,

Fill fluid

Silicone oil
Synthetic oil

Material housing

Die-cast aluminum
Stainless steel

Communication

4...20 mA HART

Certificates / Approvals

ATEX, FM, CSA, IECEx, NEPSI, INMETRO

Design approvals

NACE MR0175,
EN10204-3.1,

Hygienic approvals

EHEDG
3A

Measuring principle

Differential pressure

Characteristic / Application

Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

Supply / Communication

4...20 mA HART

Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Long term stability

0.05% of URL/year of individual sensor

Ambient temperature

40...+80В°C
(40... +176В°F)

Process temperature

40...+125В°C
(40 ... +257В°F)

Process pressure absolute / max. overpressure limit

160 bar (2400 psi)

Pressure measuring range

400 mbar...10 bar
(6 psi...150 psi)

Main wetted parts

316L, Alloy C

Process connection

Threads
Flange (DIN, ASME,JIS)

Process connection hygienic

DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent

Communication

4...20 mA HART

Certificates / Approvals

ATEX, FM, CSA, CSA C/US IEC Ex, NEPSI, INMETRO

Design approvals

NACE MR0175
EN10204-3.1

Hygienic approvals

FDA

Options

4-line digital display
SS- or Aluminium housing

Application limits

Use the Software Applicator Sizing Electronic DP

Comments

No comments yet