Endress+Hauser EngyCal RH33
BTU meter
1x Puls/Analog
2x RTD/Analog
Loop power supply 24V DC (+/-16%)
1x 4...20mA
2x digital (Open Collector)
160 x 80 Dot-Matrix LCD with white backlit
colour change in case of alarm event
active display area 70 x 34 mm
heat quantity and heat quantity difference
- Overview +
- Comments +
Custody transfer BTU meter for recording heat quantities of water.
Measuring principleEnergy manager
Measuring principleEnergy manager
FunctionMonitoring and billing of energy in heating and cooling applications as well as combined heating-and cooling circles.
Typical applications can be found in industries, district heating and building automation.
heat quantity and heat quantity difference
Number of applications1
Data storageyes
Calculation standardsIAPWS-97
Communicationweb server
USB
Ethernet
Modbus RTU/TCP Slave
M-Bus
Not defined
Loop power supplyLow voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%)
24 V AC (В±50%)
IP65
Input1x Puls/Analog
2x RTD/Analog
Loop power supply 24V DC (+/-16%)
1x 4...20mA
2x digital (Open Collector)
144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")
Operation3 button on site or via FieldCare
read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface)
selectable language
160 x 80 Dot-Matrix LCD with white backlit
colour change in case of alarm event
active display area 70 x 34 mm
Calculated Values:
Energy, volume, density, enthalpy & enthalpy difference, DP-Flow-Compensation, mass, temperature difference
Counters:
Volume, mass, energy, counter in case of failure
Optional:
tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy
CE
CSA GP
MID 004 (custody transfer) according EN1434 (water/other liquids)
OIML R75
Energy manager
FunctionMonitoring and billing of energy in heating and cooling applications as well as combined heating-and cooling circles.
Typical applications can be found in industries, district heating and building automation.
CE, UL listed, CSA GP, MID 004 (custody transfer) according EN1434 (water/other liquids) and OIML R75
Input1x Puls/Analog,
2x RTD/Analog,
Loop power supply 24V DC (+/-16%)
1x 4...20mA,
2x digital (Open Collector)
2x
Auxiliary power supplyLow voltage power supply: 100 bis 230 V AC (-15% / +10%); Small voltage power supply: 24 V DC (-50% / +75%), 24 V AC (В±50%)
Dimensions (wxhxd)144 x 144 x 103.1 mm
(5.67" x 5.67" x 4.06")
Calculated Values:
Energy, volume, density, enthalpy & enthalpy difference,
DP-Flow-Compensation,
mass,
temperature difference;
Counters: volume, mass, energy, counter in case of failure
Optional: tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy
3 button on site or via FieldCare; read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface), selectable language
Display160 x 80 Dot-Matrix LCD with white backlit, colour change in case of alarm event, active display area 70 x 34 mm
Otherselectronic temperature sensor matching via CvD coefficients, logbook measured values, custody transfer logbook, event logbook, limit monitoring
CalculationsIAPWS-IF97
Buy Endress+Hauser EngyCal RH33 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. delivers top-quality industrial control products. Our extensive inventory ensures you find the parts you need, with worldwide delivery options. We offer competitive prices and personalized service. Get in touch today to see how we can support your business effectively and efficiently.