Endress+Hauser Gammapilot FMG60
Radiometric level and density measurement
Radioisotope level measurement system
Process temperatureAny
Process pressure absolute / max. overpressure limitAny
Min. density of mediumAny
Max. measurement distanceUnlimited measuring range
Cascade
Any
Accuracy+/-1%
Main wetted partsNon-contact
- Overview
- Comments
Radioisotope system for non-penetrating and non-contact measurement of level, interfacial level, density and limit control of any products. Suitable for use in hazardous areas.
Compact transmitter for point level detection, continuous level, interface and density measurement.
Measuring principleRadiometric Limit
Characteristic / ApplicationCompact transmitter
SpecialitiesOptional separate housing
Supply / CommunicationAC: 90-253V
DC: 18-36V
-40...60В°C
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F)
Any
Process pressure absolute / max. overpressure limitAny
Min. density of mediumAny
Main wetted partsNon-contact
Process connectionNon-contact
Process connection hygienicNon-contact
Sensor lengthPVT scintillator 200 mm (8")
PVT scintillator 400 mm (16")
NaJ scintillator 50x50mm (2")
4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
Safety approvalsSIL1/ SIL2
ComponentsIsotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Radiometric Density
Characteristic / ApplicationCompact transmitter
with PT100 input for
temperature compensation
AC: 90-253V
DC: 18-36V
-40В°C...50В°C / 60В°C
With cooling jacket: 0В°C...120В°C
Any
Process pressure absoluteAny
Wetted partsNon-contact
HygienicNon-contact
Sensor lengthNaJ scintillator 50x50mm
PVT scintillator 200...400mm
4-20mA HART
FOUNDATION Fieldbus
PROFIBUS PA
ATEX, FM, CSA, IECEx, TIIS, NEPSI, GOST
ComponentsIsotope: FSG60
Source container: FQG60, FQG61, FQG62, FQG63, QG2000
SIL1
Measuring principleRadiometric Limit
Characteristic / ApplicationCompact transmitter
SpecialitiesInterface measurement
Supply / CommunicationDC: 90-253V
AC: 18-36V
-40...60В°C,
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F)
Any
Process pressure absolute / max. overpressure limitAny
Min. density of mediumAny
Min. conductivity of mediumAny
Main wetted partsNon-contact
Process connectionNon-contact
Process connection hygienicNon-contact
Sensor lengthPVT scintillator 200 mm
PVT scintillator 400 mm
NaI scintillator 50x50mm
4-20mA HART
FOUNDATION Fieldbus
PROFIBUS PA
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
Safety approvalsSIL1/ SIL2
ComponentsIsotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Radiometric
Characteristic / ApplicationCompact transmitter
SpecialitiesCascading for high silos
Supply / CommunicationAC: 90-253V
DC: 18-36V
+/-1%
Ambient temperature-40...60В°C
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F
Any
Process pressure absolute / max. overpressure limitAny
Main wetted partsNon-contact
Process connectionNon-contact
Process connection hygienicNon-contact
Sensor lengthPVT scintillator
400mm...2000mm
>2000mm cascade mode
Unlimited measuring range
Cascade
4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
Safety approvalsSIL1
ComponentsIsotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Display: FHX40
Mounting accessories: FHG60
Radiometric
Characteristic / ApplicationCompact transmitter
Non-contact measuring technique, for extreme process conditions (temperature, pressure)
Interfaces liquid / liquid also with emulsion layers and interfaces liquid / solid
SpecialitiesInterface, density and mass flow measurement
Supply / CommunicationAC: 90-253V
DC: 18-36V
+/-1%
Ambient temperature-40...60В°C
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F)
Any
Process pressure absolute / max. overpressure limitAny
Main wetted partsNon-contact
Process connectionNon-contact
Process connection hygienicNon-contact
Sensor lengthPVT scintillator
400mm...2000mm
>2000mm cascade mode
Unlimited measuring range
Cascade
4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
Safety approvalsSIL1
ComponentsIsotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Display: FHX40
Mounting accessories: FHG60