Endress+Hauser Gammapilot FMG60
Radiometric level and density measurement

Endress+Hauser Gammapilot FMG60

Radioisotope level measurement system

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Max. measurement distance

Unlimited measuring range
Cascade

Min. conductivity of medium

Any

Accuracy

+/-1%

Main wetted parts

Non-contact

Item Number: Gammapilot FMG60
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Radioisotope system for non-penetrating and non-contact measurement of level, interfacial level, density and limit control of any products. Suitable for use in hazardous areas.

Compact transmitter for point level detection, continuous level, interface and density measurement.

Measuring principle

Radiometric Limit

Characteristic / Application

Compact transmitter

Specialities

Optional separate housing

Supply / Communication

AC: 90-253V
DC: 18-36V

Ambient temperature

-40...60В°C
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Process connection hygienic

Non-contact

Sensor length

PVT scintillator 200 mm (8")
PVT scintillator 400 mm (16")
NaJ scintillator 50x50mm (2")

Communication

4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC

Safety approvals

SIL1/ SIL2

Components

Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66

Measuring principle

Radiometric Density

Characteristic / Application

Compact transmitter
with PT100 input for
temperature compensation

Supply / Communication

AC: 90-253V
DC: 18-36V

Ambient temperature

-40В°C...50В°C / 60В°C
With cooling jacket: 0В°C...120В°C

Process temperature

Any

Process pressure absolute

Any

Wetted parts

Non-contact

Hygienic

Non-contact

Sensor length

NaJ scintillator 50x50mm
PVT scintillator 200...400mm

Output

4-20mA HART
FOUNDATION Fieldbus
PROFIBUS PA

Certificates / Approvals

ATEX, FM, CSA, IECEx, TIIS, NEPSI, GOST

Components

Isotope: FSG60
Source container: FQG60, FQG61, FQG62, FQG63, QG2000

Other approvals and certificates

SIL1

Measuring principle

Radiometric Limit

Characteristic / Application

Compact transmitter

Specialities

Interface measurement

Supply / Communication

DC: 90-253V
AC: 18-36V

Ambient temperature

-40...60В°C,
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Min. conductivity of medium

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Process connection hygienic

Non-contact

Sensor length

PVT scintillator 200 mm
PVT scintillator 400 mm
NaI scintillator 50x50mm

Communication

4-20mA HART
FOUNDATION Fieldbus
PROFIBUS PA

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC

Safety approvals

SIL1/ SIL2

Components

Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66

Measuring principle

Radiometric

Characteristic / Application

Compact transmitter

Specialities

Cascading for high silos

Supply / Communication

AC: 90-253V
DC: 18-36V

Accuracy

+/-1%

Ambient temperature

-40...60В°C
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Process connection hygienic

Non-contact

Sensor length

PVT scintillator
400mm...2000mm
>2000mm cascade mode

Max. measurement distance

Unlimited measuring range
Cascade

Communication

4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC

Safety approvals

SIL1

Components

Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Display: FHX40
Mounting accessories: FHG60

Measuring principle

Radiometric

Characteristic / Application

Compact transmitter
Non-contact measuring technique, for extreme process conditions (temperature, pressure)

Interface measurement

Interfaces liquid / liquid also with emulsion layers and interfaces liquid / solid

Specialities

Interface, density and mass flow measurement

Supply / Communication

AC: 90-253V
DC: 18-36V

Accuracy

+/-1%

Ambient temperature

-40...60В°C
(-40...140В°F),
With cooling jacket:
0...120В°C
(32...248В°F)

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process connection

Non-contact

Process connection hygienic

Non-contact

Sensor length

PVT scintillator
400mm...2000mm
>2000mm cascade mode

Max. measurement distance

Unlimited measuring range
Cascade

Communication

4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC

Safety approvals

SIL1

Components

Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Display: FHX40
Mounting accessories: FHG60

Comments

No comments yet

Write a comment