Endress+Hauser Dipfit CPA111
Immersion assembly
Max. 80 В°C (176 В°F)
Process pressureMax. 4 bar at 20В°C
(Max. 58 psi at 68В°F)
- Overview
- Comments
Universal assembly for the water and wastewater industry.
Measuring principlePotentiometric
ApplicationWater, waste water, process
InstallationImmersion assembly
CharacteristicFor open and closed tanks and channels
DesignBayonet technology, 3 electrode installation locations,
120 mm electrodes, variable holder length, integrated spray cleaning CPR31, external spray cleaning CPR30, process connection with fix or adjustable flange
Sensor holder: PP-GF 20
Immersion tube: PP
Length: 500 to 3000 mm (19.7 to 118 inch), special lengths on request
Process temperatureMax. 80 В°C (176 В°F)
Process pressureMax. 4 bar at 20В°C
(Max. 58 psi at 68В°F)
Suspended assembly, lap joint flange DN100
Pressurized flange DN100/PN4, adjustable flange DN100
Sensor ORP / Redox
ApplicationWater, waste water, process
InstallationImmersion assembly
CharacteristicFor open and closed tanks and channels
DesignBayonet technology, 3 electrode installation locations,
120 mm electrodes, variable assembly length, integrated spray cleaning CPR31, external spray cleaning CPR30, process connection with fix or adjustable flange
Sensor holder: PP-GF 20
Immersion tube: PP
O-ring: VITON
500 to 3000 mm (19.7 to 118 inch), special lengths on request
Process temperaturemax. 80В°C
( 176В°F)
max. 4 bar at 20В°C
(58 psi at 68В°F)
- Suspended assembly - lap joint flange DN100- pressurized flange DN100/PN4 - adjustable flange DN100
Comments