Endress+Hauser iTHERM TM402
Imperial Hygienic Thermometer, US style
class A acc. to IEC 60751
Response timedepending on configuration
Max. process pressure (static)at 20 В°C: 40 bar (580 psi)
Operating temperature rangePT100:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
up to 15.5" (317,5mm)
others on request
- Overview
- Comments
For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
Measuring principleResistance Temperature Detector
Characteristic / Applicationimperial style
hygienic applications
aseptic applications
hygienic process connections
with neck
without (direct immersion)
Insert / probewithout exchangeable insert
Outer diameter protection tube / Insert1/4'' (6,35 mm)
3/8'' (9,53 mm)
up to 15.5" (317,5mm)
others on request
316L
Process connectionTriclamp
Clamp-connections according to ISO2852
G3/4" Liquiphant
G1" Liquiphant
Varivent
straight
reduced
30 Ојin (0,76 Ојm)
15 Ојin (0,38 Ојm)
PT100:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
at 20 В°C: 40 bar (580 psi)
Accuracyclass A acc. to IEC 60751
Response timedepending on configuration
Integration head transmitteryes (4 ... 20 mA, HART)
CertificationSIL (transmitter only)
Comments
No comments yet