Endress+Hauser Levelflex FMP52
Guided radar measurement Time-of-Flight
Micropulse level gauge
AccuracyRod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
-50...+200 В°C
(-58...+392 В°F)
Vacuum...40 bar
(Vacuum...580 psi)
Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9
Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA
- Overview
- Comments
Levelflex M micropulse level transmitter for general measurement of overflow and interfacial level of liquid products. Stable and reliable in the case of unstable product surfaces and the presence of foam, as well as in the case of products with changing properties.
Coated probe for use in aggressive liquids.
Measuring principleGuided radar
Characteristic / ApplicationPremium device coated for corrosive media
Rod probe, Rope probe
Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.
Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level
Heartbeat Technology,
BluetoothВ® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
BluetoothВ® wireless technology and App (optional)
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
-40...+80 В°C
(-40...+176 В°F)
-50...+200 В°C
(-58...+392 В°F)
Vacuum...40 bar
(Vacuum...580 psi)
Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA
Flange:
ASME 1 1/2"...6",
DN50...DN100,
JIS 10K
Tri-Clamp
DIN11851
Rod probe: 4 m (13 ft)
Rope probe: 45 m (148 ft)
Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
BluetoothВ® wireless technology
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
Safety approvalsOverfill protection WHG
SIL
EN 10204-3.1
ASME B31.1, B31.3
AD2000
3A, EHEDG
Marine approvalGL/ ABS/ LR/ BV/ DNV
OptionsSensor remote with 3 m/ 9 ft cable,
Gas-tight feed through,
Remote operation via SmartBlue App using BluetoothВ®
Application limits
Comments
No comments yet