Endress+Hauser Liquiline M CM42
1-channel transmitter

Endress+Hauser Liquiline M CM42

Fluid Conductivity Transducer

Input

One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later

Ingres protection

IP66/67, NEMA 4X

Item Number: Liquiline M CM42
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Modular converter with two-wire connection. For use in all industrial processes, including hazardous areas.

Two-wire field device for hazardous and non-hazardous area use in chemicals, life sciences and food.

Measuring principle

ISFET

Application

Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

Potentiometric pH measurement

Design

Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Liquiline is developed acc. to the international safety standard IEC 61508

Material

Plastic or stainless steel housing with EPDM sealings

Dimension

Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch

Temperature sensor

Applicable:
Pt100, Pt1000, NTC 30K

Ex certification

: ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingres protection

IP66/67, NEMA 4X

Input

One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later

Measuring principle

Sensor ORP / Redox

Application

Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

ORP measurement

Design

Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Liquiline is developed acc. to the international safety standard IEC 61508

Material

Plastic or stainless steel housing with EPDM sealings

Dimension

Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch

Temperature sensor

Applicable:
Pt100, Pt1000, NTC 30K

Ex certification

ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingres protection

IP66/67, NEMA 4X

Input

One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

1/2 x 4 to 20 mA, HART, Profibus, FF
Additional second output possible, also later

Measuring principle

Conductive

Application

Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

Resistance measurement

Design

Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Liquiline is developed acc. to the international safety standard IEC 61508

Material

Plastic or stainless steel housing with EPDM sealings

Dimension

Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch

Temperature sensor

Applicable:
Pt100, Pt1000

Ex certification

ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingres protection

IP66/67, NEMA 4X

Input

One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later

Measuring principle

Amperometric oxygen measurement

Application

Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

Connection of oxygen sensors with Memosens coupling

Design

Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Liquiline is developed acc. to the international safety standard IEC 61508

Material

Plastic or stainless steel housing with EPDM sealings

Dimension

Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch

Ex certification

ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingres protection

IP66/67, NEMA4X

Input

One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later

Comments

No comments yet

Write a comment