Endress+Hauser Liquiphant FTL50
Vibronic Point level detection

Endress+Hauser Liquiphant FTL50
We ship to United States of America!

Vibrating level gauge

Process temperature

-50 В°C...+150 В°C
(-58 В°F...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...64 bar
(Vacuum...928 psi)

Min. density of medium

0.5g/cmВі(0.4g/cmВі option)

Item Number: Liquiphant FTL50
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

Liquiphant M FTL50 is vibration level limit switch for liquids of all types. Suitable for food and pharmaceutical industries, as well as in hazardous areas.

Compact vibration point level switch for liquids in all industries.

Measuring principle

Vibration Density

Characteristic / Application

Liquiphant M Density
with Density Computer FML621
Temperature and pressure measurement
Modular housing concept
Wide range of process connections

Supply / Communication

Transmitter power supply (MUS)

Ambient temperature

-50...70В°C
-50...60В°C for hazardous applications

Process temperature

0...80В°C (validity of accuracy data)
-50...0В°C /80...150В°C (with reduced technical data)

Process pressure absolute

0...25 bar
>25...64 bar (with reduced technical data)

Wetted parts

316L/C4

Sensor length

Compact: 50.5 mm

Output

Pulse

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Specialities

Commissioning with ReadWin2000

Components

Density Computer FML621

Other approvals and certificates

SIL2/ SIL3

Measuring principle

Vibration Liquids

Characteristic / Application

Modular housing concept
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g. Ex,WHG)
compact, e.g. pipes

Specialities

Foamdetection
Detekt a densitychange
second line of defense

Supply / Communication

PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC or 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM

Ambient temperature

-50 В°C...+70 В°C
(-58 В°F...+158 В°F)

Process temperature

-50 В°C...+150 В°C
(-58 В°F...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...64 bar
(Vacuum...928 psi)

Min. density of medium

0.5g/cmВі(0.4g/cmВі option)

Main wetted parts

316L, Alloy

Process connection

Thread:
G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
Flange:
DN25...DN100,
ASME 1"...4",
JIS 25A...100A

Process connection hygienic

Tri-Clamp ISO2852

Communication

PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC or 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvals

SIL2/ SIL3

Design approvals

EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000

Marine approval

GL/ ABS/ DNV

Options

Heavy duty stainless steel housing mainly for the oil and gas industry

Components

FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR

Successor

Liquiphant FTL51B


Buy Endress+Hauser Liquiphant FTL50 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com provides top-quality industrial control components. Our online catalog features a wide range of products to meet your specific requirements. Enjoy the convenience of consolidated shipments and competitive pricing. Join our satisfied customers who rely on us for their automation solutions.

Comments

No comments yet

Write a comment