Endress+Hauser LNGmass
Coriolis flowmeter

Endress+Hauser LNGmass
Max. measurement error

Mass flow (liquid): В±0.15 %
Volume flow (liquid): В±0.15 %
(Reference condition)

Measuring range

0 to 18 000 kg/h (0 to 660 lb/min)

Medium temperature range

196 to +125 В°C (320 to +257 В°F)

Max. process pressure

PN 40, Class 300

Wetted materials

Measuring tubes: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Item Number: LNGmass
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Refueling application flowmeter with easy system integration.

Measuring principle

Coriolis

Product headline

Refueling application flowmeter with easy system integration. Accurate measurement of cryogenic gases in refueling applications.

Sensor features

Excellent operational safety reliable under extreme ambient conditions. Fewer process measuring points multivariable measurement (flow, density, temperature). Space-saving installation no in/outlet run needs. Flow rates up to 18 000 kg/h (660 lb/min). Medium temperature down to 196 В°C (321 В°F).

Transmitter features

Space...saving transmitter full functionality on the smallest footprint. Fast commissioning pre...configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485.

Nominal diameter range

DN 8 to 25 (в…њ to 1")

Wetted materials

Measuring tubes: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow

Max. measurement error

Mass flow (liquid): В±0.15 %
Volume flow (liquid): В±0.15 %
(Reference condition)

Measuring range

0 to 18 000 kg/h (0 to 660 lb/min)

Max. process pressure

PN 40, Class 300

Medium temperature range

196 to +125 В°C (320 to +257 В°F)

Ambient temperature range

40 to +60 В°C (40 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

AlSi10Mg, coated

Degree of protection

IP66/67, type 4X enclosure

Display/Operation

No local operation
Configuration via operating tools possible

Outputs

None

Inputs

None

Digital communication

Modbus RS485

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus, NEPSI, EAC

Other approvals and certificates

3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
CRN

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Material certificates

3.1 material

Comments

No comments yet

Write a comment