Endress+Hauser LPGmass
Coriolis flowmeter

Endress+Hauser LPGmass
Max. measurement error

Mass flow (liquid): В±0.2 %
Volume flow (liquid): В±0.3 %

Measuring range

0 to 45 000 kg/h (0 to 1650 lb/min)

Medium temperature range

40 to +125 В°C (40 to +257 В°F)

Max. process pressure

PN 40, Class 300, 63K

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Item Number: LPGmass
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The refueling and distribution application flowmeter with easy system integration.

Measuring principle

Coriolis

Product headline

The refueling and distribution application flowmeter with easy sytem
integration. Accurate measurement of liquefied petroleum gas in refueling
and distribution applications.

Sensor features

Excellent operational safety reliable under extreme ambient conditions.
Fewer process measuring points multivariable measurement (flow,
density, temperature). Space...saving installation no in/outlet run needs.
Flow rates up to 45 000 kg/h (1654 lb/min). Volume flow calculation
according to API table 53.

Transmitter features

Easy operation reduced to application needs. Fast commissioning pre...configured devices. Automatic recovery of data for servicing. Robust, ultra...compact transmitter housing. Pulse output and Modbus RS485.

Nominal diameter range

DN 8 to 40 (ВівЃ„в‚€ to 1ВЅ")

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow

Max. measurement error

Mass flow (liquid): В±0.2 %
Volume flow (liquid): В±0.3 %

Measuring range

0 to 45 000 kg/h (0 to 1650 lb/min)

Max. process pressure

PN 40, Class 300, 63K

Medium temperature range

40 to +125 В°C (40 to +257 В°F)

Ambient temperature range

40 to +60 В°C (40 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

Powder...coated die...cast aluminium

Degree of protection

IP67, type 4X enclosure

Display/Operation

No local operation
Configuration via operating tools possible

Outputs

Pulse/frequency/switch output (passive), phase...shifted pulse

Inputs

None

Digital communication

Modbus RS485

Power supply

DC 10 to 30 V
AC 20 to 28 V

Hazardous area approvals

ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL

Other approvals and certificates

3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody
transfer
PED, CRN

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material