Endress+Hauser Memosens CYK10
Digital measuring cable
Measuring cable for Memosens sensors
Memosens data cable for all sensors with Memosens plug-in head.
- Overview +
- Comments +
Kit for use with sensors supporting Memosens digital data transmission and processing technology. Measuring, extension cable, junction box.
Measuring principleFree chlorine
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
Cable sheath: TPE
Junction box: aluminum
Diameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
-25 to 135 В°C (-13 to 277 В°F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Additional certificationsAlso available as TГњV approved SIL version
Measuring principleSensor ORP / Redox
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals.
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
CharacteristicInductive, digital transmission of measurement signals and energy.
Not influenced by moisture, EMC-fields and corrosion
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
Cable sheath: TPE
Junction box: aluminum
Diameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
-25 to 135 В°C (-13 to 277 В°F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Also available as TГњV approved SIL version
Measuring principlePotentiometric
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
High impedance cable not necessary
DesignEasy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
Cable sheath: TPE
Junction box: aluminum
Diameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
-25 to 135 В°C (-13 to 277 В°F)
Process pressuremax. 50 bar/725 psi at 135В°C/275В°F.
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
IP68
Additional certificationsAlso available as TГњV approved SIL version
Measuring principleConductive
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
Cable sheath: TPE
Junction box: aluminum
Diameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
-25 to 135 В°C (-13 to 277 В°F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Also available as TГњV approved SIL version
Measuring principleAmperometric oxygen measurement
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
Cable sheath: TPE
Junction box: aluminum
Diameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
-25 ... 135 В°C (-13 ... 277 В°F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Also available as TГњV approved SIL version
Buy Endress+Hauser Memosens CYK10 with the best possible price and delivery terms on eltra-trade.com
Find the industrial control components you need at eltra-trade.com. Our catalog offers a variety of sizes and types, all available for prompt delivery. Enjoy competitive pricing and excellent customer service. Trust us to fulfill your automation equipment requirements efficiently and reliably.
Comments
No comments yet