Endress+Hauser Soliwave FQR57
Microwave barrier transmitter

Endress+Hauser Soliwave FQR57
Process temperature

Non-contact installation: any
Within installation:
-40 В°C...+70 В°C
(-40 В°F...+158 В°F)
With HT-Adapter:
up to +450 В°C (+842 В°F)

Process pressure absolute / max. overpressure limit

Non-contact installation: any
Within installation:
0.5 bar...6.8 bar
(7.2 psi ... 99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs.

Min. density of medium

Solid weight: > 10 g/l

Item Number: Soliwave FQR57
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Transmitter for non-contact point level detection and bulk flow monitoring.

Measuring principle

Microwave barrier

Characteristic / Application

Transmitter
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Non-contact installation:
Waves emitted from outside
Within installation:
Waves emitted within installation (contact)

Specialities

With optional integrated bulk flow monitoring
Parallel mode with up to 5 channels
Detection range limit: max. 100 m
Detection range flow: max. 10 m, depending on bulk solids

Supply / Communication

Via process transmitter with control unit Nivotester FTR525

Ambient temperature

-40 В°C...+70 В°C
(-40 В°F...+158 В°F)

Process temperature

Non-contact installation: any
Within installation:
-40 В°C...+70 В°C
(-40 В°F...+158 В°F)
With HT-Adapter:
up to +450 В°C (+842 В°F)

Process pressure absolute / max. overpressure limit

Non-contact installation: any
Within installation:
0.5 bar...6.8 bar
(7.2 psi ... 99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs.

Min. density of medium

Solid weight: > 10 g/l

Main wetted parts

Non-contact installation:
No wetted parts
Within installation:
316Ti, PTFE or Ceramic

Process connection

Threads:
1-1/2" R, 1-1/2" G, 1-1/2" NPT

Communication

Via process transmitter with control unit Nivotester FTR525

Certificates / Approvals

ATEX, IEC Ex

Design approvals

EN10204-3.1

Options

Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55

Components

Transceiver: FDR57
Process transmitter: FTR525

Application limits

Solid weight: < 10 g/l

Comments

No comments yet

Write a comment