Endress+Hauser Multicap T DC11TEN
Level sensor
- Overview
- Comments
Measuring principle
Capacitive Liquid
Characteristic / Application
Fully insulated rod probe, suitable for storage and buffer tanks
T: Standard application
E: European Certificate (EEx d, EEx ia)
N: No additional safety feature
Specialities
Foam detection
Supply / Communication
3-wire
PFM
Ambient temperature
Standard:
-40 В°C ... 70 В°C
With separate housing:
-50 В°C ... 120 В°C
Process temperature
-50 В°C ... 200 В°C
Process pressure absolute / max. overpressure limit
Vacuum ... 25 bar
Main wetted parts
Insulation material: PTFE
316L
Process connection
G 3/4A, G 1A /NPT 3/4", NPT 1"
Flange from DN25.../ASME 1".../JIS...
Process connection hygienic
Tri-Clamp ISO2852
Dairy coupling
Sensor length
Total length of probe 3 m
Communication
3-wire
PFM
Certificates / Approvals
ATEX
WHG
Options
Ground tube, Separate housing (HTC)
Components
Transmitter
3-wire: FTC325
PFM: FTC325, FTC625, FTC470Z, FTC471Z
Successor
FTI51
Application limits
Notice the pressure and temperature derating.
Notice for non conductive medium the DK.
Measuring principle
Capacitive
Characteristic / Application
Fully insulated rod probe, suitable for storage and buffer tanks
T: Standard application
E: European Certificate (EEx d, EEx ia)
N: No additional safety feature
Specialities
Foam detection
Supply / Communication
HART
PROFIBUS PA
3-wire
PFM
Linearity error for conductive liquids
< 1% at 1m
Ambient temperature
Standard:
-40 В°C ... 70 В°C
With separate housing:
-50 В°C ... 120 В°C
Process temperature
-50 В°C ... 200 В°C
Process pressure absolute / max. overpressure limit
Vacuum ... 25 bar
Main wetted parts
Insulation material: PTFE
316L
Process connection
G 3/4A, G 1A /NPT 3/4", NPT 1"
Flange ab DN25.../ASME 1".../JIS...
Process connection hygienic
Tri-Clamp ISO2852
Dairy coupling
Sensor length
Total length of probe 3 m
Max. measurement distance
0.1 m ... 3.0 m
Communication
HART
PROFIBUS PA
3-wire
PFM
Certificates / Approvals
ATEX
WHG
Options
Ground tube, Separate housing (HTC)
Components
Transmitter
3-wire: FMC420
PFM: FMX570, FMC671Z, FMC661
Successor
FMI51
Application limits
Notice the pressure and temperature derating.
Notice for non conductive medium the DK.
Comments
No comments yet