Endress+Hauser TC12
Modular TC thermometer
Thermocouple
Accuracyclass 1 acc. to IEC 60584
Response timedepending on configuration
t50 = 6 s
t90 = 13 s
at 20 В°C: 40 bar (580 psi)
Operating temperature rangeType K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)
up to 10.000,00 mm (393,70'')
- Overview
- Comments
Universal thermocouple. Applicable in all industries. Various data protocols (Profibus PA, HART, FOUNDATION Fieldbus).
Comprehensive and common temperature measurement technology for almost all branches of industry.
Measuring principleThermocouple
Characteristic / Applicationmetric style
modular temperature assembly
universal range of application
suitable for hazardous areas
process connection as compression fitting
without neck
incl. thermowell / protection tube (metal)
welded protection tube
Insert / probemineral insulated (MI), flexible
Outer diameter protection tube / Insert9,0 mm (0,35'')
11,0 mm (0,43'')
12,0 mm (0,47'')
up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell1.4404 (316L)
1.4571 (316Ti)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
Not defined
Process connectioncompression fitting:
G1/2"
G1"
R1/2"
R3/4"
straight
reduced
tapered
0,8 Ојm (31,5 Ојin.)
Operating temperature rangeType K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)
at 20 В°C: 40 bar (580 psi)
Accuracyclass 1 acc. to IEC 60584
Response timedepending on configuration
t50 = 6 s
t90 = 13 s
yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsATEX II
ATEX IECEx
NEPSI
IECEx
EAC Ex
Gost Metrology
SIL (transmitter only)
Comments