Endress+Hauser TAF12T
High temperature TC thermometer

Endress+Hauser TAF12T

Thermocouple

Accuracy

class 2 acc. to IEC 60584

Max. process pressure (static)

at 20 В°C: 1 bar (15 psi)

Operating temperature range

Type S:
0 C ...1.600 C
(32 F ...2.912 F)
Type R:
0 C ...1.600 C
(32 F ...2.912 F)
Type B:
600 C ...1.700 C
(1.112 F ...3.092 F)

Max. immersion length on request

up to 3.500,00 mm (137,80'')

Item Number: TAF12T
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Modular temperature sensor Omnigrad S designed for high temperature applications. Ceramic thermowell and various process connections. Protection of the sensing element with non-porous materials.

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries.

Measuring principle

Thermocouple

Characteristic / Application

metric style
modular temperature assembly
high temperature (furnace)
ncl. triple ceramic thermowell

Thermowell / protection tube

ceramic protection tube and 2x inner tube

Insert / probe

ceramic capilarry, rigid

Outer diameter protection tube / Insert

24,0 mm (0,94")
26,0 mm (1,02")

Max. immersion length on request

up to 3.500,00 mm (137,80'')

Material protection tube/ thermowell

Ceramic (C530/C610/C799)

Process connection

compression fitting:
G11/2"

Tip shape

straight

Operating temperature range

Type S:
0 C ...1.600 C
(32 F ...2.912 F)
Type R:
0 C ...1.600 C
(32 F ...2.912 F)
Type B:
600 C ...1.700 C
(1.112 F ...3.092 F)

Max. process pressure (static)

at 20 В°C: 1 bar (15 psi)

Accuracy

class 2 acc. to IEC 60584

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Certification

SIL (transmitter only)

Comments

No comments yet

Write a comment