Endress+Hauser TC61
Explosion-proof TC thermometer with DIN thermowell

Endress+Hauser TC61

Explosion proof thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 3 s
t90 = 7 s

Max. process pressure (static)

at 20 В°C: 100 bar (1.450 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Item Number: TC61
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Explosion-proof thermocouple with threaded and flanged connections Omnigrad S. Compression fitting. Suitable for use in explosive industries.

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry.

Measuring principle

Thermocouple

Characteristic / Application

metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
with neck
incl. thermowell / protection tube (metal)

Thermowell / protection tube

welded protection tube

Insert / probe

mineral insulated (MI), flexible

Outer diameter protection tube / Insert

9,0 mm (0,35'')
11,0 mm (0,43'')
12,0 mm (0,47'')

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Material protection tube/ thermowell

1.4404 (316L)
1.4571 (316Ti)
Alloy 600 (2.4816)
Alloy C276 (2.4819)

Optional coating

Not defined

Process connection

male thread:
G1/2"
G3/4"
G1"
NPT1/2"
NPT3/4"
M20x1,5
compression fitting:
G1/2"
G1"
flange:
DN25 PN40 B1 (EN1092)
DN40 PN40 B1(EN1092)
DN50 PN40 B1 (EN1092)
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)

Tip shape

straight
reduced
tapered

Surface roughness Ra

0,8 Ојm (31,5 Ојin.)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. process pressure (static)

at 20 В°C: 100 bar (1.450 psi)

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 3 s
t90 = 7 s

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

ATEX II
IECEx
NEPSI
EAC Ex
Explosion proof

Certification

Gost Metrology
SIL (transmitter only)

Comments

No comments yet

Write a comment