Endress+Hauser TC62
Explosion-proof thermocouple thermometer
Explosion proof thermocouple
Accuracyclass 1 acc. to IEC 60584
Response timedepending on configuration
t50 = 3 s
t90 = 7 s
at 20 В°C: 500 bar (7.252 psi)
Operating temperature rangeType K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)
up to 30.000,00 mm (1.181,10'')
- Overview
- Comments
Explosion-proof thermocouple Omnigrad S. Diameter 6 mm. For screwing into a thermowell. Suitable for use in explosive industries.
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry.
Measuring principleThermocouple
Characteristic / ApplicationUS style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
with neck
to use with thermowell
to use with thermowell
Insert / probereplaceable (without process interruption)
Outer diameter protection tube / InsertInsert Diameter
6,0 mm (0,24'')
up to 30.000,00 mm (1.181,10'')
Material protection tube/ thermowellNot defined
Optional coatingNot defined
Process connectionmale thread:
NPT1/2"
straight
Surface roughness Ra0,8 Ојm (31,5 Ојin.)
Operating temperature rangeType K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)
at 20 В°C: 500 bar (7.252 psi)
Accuracyclass 1 acc. to IEC 60584
Response timedepending on configuration
t50 = 3 s
t90 = 7 s
yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsATEX II
IECEx
NEPSI
EAC Ex
Explosion proof
Gost Metrology
SIL (transmitter only)
Comments
No comments yet