Endress+Hauser TC88
Modular thermometer

Endress+Hauser TC88

Thermocouple

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 1 s
t90 = 2 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Item Number: TC88
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Universal thermocouple Omnigrad S. Diameter 6 mm or 3 mm. For use with a thermowell (to be ordered bleached). With threaded connection or compression fitting. For all industries.

Comprehensive and common temperature measurement technology for almost all branches of industry.

Measuring principle

Thermocouple

Characteristic / Application

metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
threaded process connection
with neck
to use with thermowell

Thermowell / protection tube

to use with thermowell

Insert / probe

mineral insulated (MI), flexible

Outer diameter protection tube / Insert

Insert Diameter
3,0 mm (0,12'')
6,0 mm (0,24'')

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Material protection tube/ thermowell

1.4404 (316L)
1.4571 (316Ti)
Alloy 600

Optional coating

Not defined

Process connection

male thread:
G1/2"
NPT1/2"
M14x1.5
M18x1.5

Tip shape

straight

Surface roughness Ra

0,8 Ојm (31,5 Ојin.)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Accuracy

class 1 acc. to IEC 60584

Response time

depending on configuration
t50 = 1 s
t90 = 2 s

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

ATEX II
NEPSI
IECEx
NEPSI
EAC Ex

Certification

Gost Metrology
SIL (transmitter only)

Comments

No comments yet