Endress+Hauser TR65
Explosion-proof Pt100 thermometer

Endress+Hauser TR65

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

t50 = 2 s
t90 = 5 s

Max. process pressure (static)

at 20 В°C: 80 bar (1.160 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Item Number: TR65
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Explosion-proof resistance thermometer for measuring the temperature of gaseous and liquid media Omnigrad S. Diameter 6 mm or 3 mm. For screwing into a thermowell. Ideal for applications in explosive industries: chemical, oil production and refining.

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry.

Measuring principle

Resistance Temperature Detector

Characteristic / Application

metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
without neck

Thermowell / protection tube

without (not intended to use with thermowell)

Insert / probe

mineral insulated (MI), flexible

Outer diameter protection tube / Insert

3,0 mm (0,12'')
6,0 mm (0,24'')

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Material protection tube/ thermowell

1.4404 (316L)

Process connection

male thread:
NPT1/2"
NPT3/4"
M20x1,5
compression fitting:
NPT1/2"
NPT3/4"

Tip shape

straight

Surface roughness Ra

Not defined

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. process pressure (static)

at 20 В°C: 80 bar (1.160 psi)

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

t50 = 2 s
t90 = 5 s

Integration head transmitter

yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

ATEX II
IECEx
NEPSI
EAC Ex
Explosion proof

Certification

Gost Metrology
SIL (transmitter only)

Comments

No comments yet