Endress+Hauser TA535
Thermowell for temperature sensors

Endress+Hauser TA535

Protective tube thermowell

Max. process pressure (static)

100 bar (1450 psi)

Maximum standard immersion length

5.000 mm (196,85")

Max. immersion length on request

10.000 mm (393,7")

Item Number: TA535
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Welded metal thermowell. To protect the thermometer from corrosive and mechanical effects of the working environment. Threaded connection to process and thermometer. Cylindrical shape.

For use in general purpose industrial applications and processes generating medium to high stress.

Measuring principle

Fabricated Thermowell

Characteristic / Application

metric style
threaded process connection
hexagonal extension

Head connection

internal thread:
1/2" NPT
3/4" NPT
M20x1.5

Maximum standard immersion length

5.000 mm (196,85")

Max. immersion length on request

10.000 mm (393,7")

Process connection

thread:
G1/2"
G3/4"
1/2"NPT
3/4" NPT
M20x1,5

Thermowell root diameter

9 mm (0,35")
10 mm (0,39")
12 mm (0,47")

Medium contact material

1.4404 (316L)

Wetted part finishing (Ra)

< 1.6 Вµm (63.00 Вµin)

Tip shape

straight

Temperature range

-200...650 В°C (-328...1.202 В°F)

Max. process pressure (static)

100 bar (1450 psi)

Max. process pressure at 400 В°C

depends on process connection

Comments

No comments yet