Endress+Hauser TW251
Protection tube for temperature sensors
Protective tube thermowell
Max. process pressure (static)50 bar (725 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
- Overview
- Comments
Protective thermowell. Carries out protection of the thermometer from corrosive and mechanical influences of a working environment. For general industrial use.
The protection tube with built-in compression fitting allows varying types of probes to be applied.
Measuring principleFabricated Thermowell
Characteristic / Applicationmetric style
for probes with diameter 6 mm (0,24") and 9 mm (0,35")
threaded or welded process connection
compression fitting
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
Process connectionthread:
G1/4"
G1/2"
1/2" NPT
weld-in adapter cylindrical
weld-in adapter spherical
6 mm (0,24")
9 mm (0,35")
1.4404 (316L)
Wetted part finishing (Ra)< 0.4 Ојm (15.75 Ојin)
< 0.8 Ојm (31.50 Ојin)
< 1.2 Ојm (47.25 Ојin)
straight
reduced
tapered
-200...650 В°C (-328...1.202 В°F)
Max. process pressure (static)50 bar (725 psi)
Max. process pressure at 400 В°Cdepends on process connection
Comments