Endress+Hauser Proline Cubemass C 100
Coriolis flowmeter

Endress+Hauser Proline Cubemass C 100

Measuring range

0 to 1000 kg/h (0 to 37 lb/min)

Medium temperature range

50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 300, 10K, 400 bar (5800 psi)

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)

Item Number: Proline Cubemass C 100
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Compact sensor for smallest quantities with an ultra-compact transmitter.

Measuring principle

Coriolis

Product headline

Compact sensor for smallest quantities with an ultra-compact transmitter.
Measuring accurately smallest quantities of liquids and gases.

Sensor features

Space-saving installation compact single-tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Suitable for skids lightweight sensor.
Nominal diameter: DN 1 to 6 . Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 В°C (+401 В°F).

Transmitter features

Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Pre...configured plug connector. Local display available.

Nominal diameter range

DN 1 to 6

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3

Measuring range

0 to 1000 kg/h (0 to 37 lb/min)

Max. process pressure

PN 40, Class 300, 10K, 400 bar (5800 psi)

Medium temperature range

-50 to +205 В°C (-58 to +401 В°F)

Ambient temperature range

Standard: -40 to +60 В°C (-40 to +140 В°F)
Option: -50 to +60 В°C (-58 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304)

Degree of protection

Standard: IP66/67, type 4X enclosure

Display/Operation

4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible

Outputs

4...20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI

Product safety

CE, C-Tick

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)

Pressure approvals and certificates

CRN

Material certificates

3.1 material

Comments

No comments yet

Write a comment