Endress+Hauser Proline Cubemass C 300
Coriolis flowmeter
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
50 to +205 В°C (58 to +401 В°F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
- Overview
- Comments
Compact sensor for smallest quantities with a compact, easily accessible transmitter.
Measuring principle
Coriolis
Product headline
Compact sensor for smallest quantities with a compact, easily accessible transmitter.
Measuring accurately smallest quantities of liquids and gases.
Sensor features
Space-saving installation compact single-tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Suitable for skids lightweight sensor.
Nominal diameter: DN 1 to 6 . Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 В°C (+401 В°F).
Transmitter features
Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range
DN 1 to 6
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cm3
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range
-50 to +205 В°C (-58 to +401 В°F)
Ambient temperature range
Standard: -40 to +60 В°C (-40 to +140 В°F)
Option: -50 to +60 В°C (-58 to +140 В°F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs
Status input
4-20 mA input
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)"
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Pressure approvals and certificates
CRN
Material certificates
3.1 material
Comments
No comments yet