Endress+Hauser Proline Promag P 10
Electromagnetic flowmeter

Endress+Hauser Proline Promag P 10
Max. measurement error

Volume flow (standard): В±0.5 % o.r.В± 1 mm/s (0.04 in/s)

Measuring range

4 dmВі/min to 9600 mВі/h (1 gal/min to 44 000 gal/min)

Medium temperature range

Liner material PFA: 20 to +150 В°C (4 to +302 В°F)
Liner material PTFE: 40 to +130 В°C (40 to +266 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

Item Number: Proline Promag P 10
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

Flowmeter for basic process applications with easy-to-use operation concept.

Measuring principle

Electromagnetic

Product headline

Flowmeter for basic process applications with easy-to-use operation concept.
Dedicated to chemical and process applications with corrosive liquids.

Sensor features

Diverse applications wide variety of wetted materials. Energy-saving flow measurement no pressure loss due to cross section constriction. Maintenance-free no moving parts.
Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.

Transmitter features

Optimum usability operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning guided parameterization in advance and in the field. Integrated verification Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.

Nominal diameter range

DN 15 to 600 (ВЅ to 24")

Wetted materials

Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

Measured variables

Volume flow, conductivity, mass flow

Max. measurement error

Volume flow (standard): В±0.5 % o.r.В± 1 mm/s (0.04 in/s)

Measuring range

4 dmВі/min to 9600 mВі/h (1 gal/min to 44 000 gal/min)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Liner material PFA: 20 to +150 В°C (4 to +302 В°F)
Liner material PTFE: 40 to +130 В°C (40 to +266 В°F)

Ambient temperature range

Flange material carbon steel: 10 to +60 В°C (+14 to +140 В°F)
Flange material stainless steel: 40 to +60 В°C (40 to +140 В°F)

Sensor housing material

DN 15 to 300 (ВЅ to 12""): AlSi10Mg, coated
DN 350 to 600 (14 to 24""): Carbon steel with protective varnish

Transmitter housing material

AlSi10Mg, coated

Degree of protection

Standard: IP66/67, Type 4X enclosure

Display/Operation

2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible

Outputs

4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA

Digital communication

HART, MODBUS RS485

Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, JPN, UK Ex

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material

Hygienic approvals and certificates

Driking water approvals: ACS; NSF61, WRAS

Comments

No comments yet

Write a comment