Endress+Hauser Proline Promag P 500
Electromagnetic flowmeter
Volume flow (standard): В±0.5 % o.r.В± 1 mm/s (0.04 in/s)
Volume flow (option): В±0.2 % o.r. В± 2 mm/s (0.08 in/s)
4 dmВі/min to 9600 mВі/h (1 gal/min to 44 000 gal/min)
Medium temperature rangeLiner material PFA: 20 to +150 В°C (4 to +302 В°F)
Liner material PFA high-temperature: 20 to +180 В°C (4 to +356 В°F)
Liner material PTFE: 40 to +130 В°C (40 to +266 В°F)
PN 40, Class 300, 20K
Wetted materialsLiner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum;
Titanium; Duplex 1.4462 (UNS S31803)
- Overview
- Comments
High-temperature flowmeter for process applications as remote version with up to 4 I/Os.
Measuring principleElectromagnetic
Product headlineHigh-temperature flowmeter for process applications as remote version with up to 4 I/Os.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Diverse applications wide variety of wetted materials. Energy...saving flow measurement no pressure loss due to cross section constriction. Maintenance...free no moving parts.
Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.
Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
DN 15 to 600 (ВЅ to 24")
Wetted materialsLiner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum;
Titanium; Duplex 1.4462 (UNS S31803)
Volume flow, conductivity, mass flow
Max. measurement errorVolume flow (standard): В±0.5 % o.r.В± 1 mm/s (0.04 in/s)
Volume flow (option): В±0.2 % o.r. В± 2 mm/s (0.08 in/s)
4 dmВі/min to 9600 mВі/h (1 gal/min to 44 000 gal/min)
Max. process pressurePN 40, Class 300, 20K
Medium temperature rangeLiner material PFA: 20 to +150 В°C (4 to +302 В°F)
Liner material PFA high-temperature: 20 to +180 В°C (4 to +356 В°F)
Liner material PTFE: 40 to +130 В°C (40 to +266 В°F)
Flange material carbon steel: 10 to +60 В°C (+14 to +140 В°F)
Flange material stainless steel: 40 to +60 В°C (40 to +140 В°F)
DN 15 to 300 (ВЅ to 12"): AlSi10Mg, coated
DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4409 (CF3M) similar to 316L
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protectionSensor remote version (standard): IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, Type 4X enclosure
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Status input
4-20 mA input
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power supplyDC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex
Product safetyCE, C-tick, EAC marking
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
LR approval, DNV GL approval, ABS approval, BV approval
Pressure approvals and certificatesPED, CRN
Material certificates3.1 material
Hygienic approvals and certificatesACS, NSF 61, WRAS
Comments