Endress+Hauser Proline Promag W 500
Electromagnetic flowmeter
Volume flow (standard): В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
Volume flow (option): В±0.2 % o.r. В± 2 mm/s (0.08 in/s), Flat Spec
9 dmВі/min to 162 000 mВі/h (2.5 gal/min to 100 000 gal/min)
Medium temperature rangeLiner material hard rubber: 0 to +80 В°C (+32 to +176 В°F)
Liner material polyurethane: 20 to +50 В°C (4 to +122 В°F)
PN 40, Class 300, 20K
Wetted materialsLiner material hard rubber: 0 to +80 В°C (+32 to +176 В°F)
Liner material polyurethane: 20 to +50 В°C (4 to +122 В°F)
Liner material PTFE: 20 to +90 В°C (4 to +194 В°F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
- Overview
- Comments
Specialist for demanding water and wastewater applications as remote version with up to 4 I/Os.
Measuring principleElectromagnetic
Product headlineSpecialist for demanding water and wastewater applications as remote version with up to 4 I/Os.
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
Dedicated to the measurement of industrial or municipal water and wastewater .
Flexible engineering sensor with fixed or lap-joint process connections. Application fitness EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability sensor compliant with industry-specific requirements.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).
Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
DN 25 to 2400 (1 to 90")
Wetted materialsLiner material hard rubber: 0 to +80 В°C (+32 to +176 В°F)
Liner material polyurethane: 20 to +50 В°C (4 to +122 В°F)
Liner material PTFE: 20 to +90 В°C (4 to +194 В°F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Volume flow, conductivity, mass flow
Max. measurement errorVolume flow (standard): В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
Volume flow (option): В±0.2 % o.r. В± 2 mm/s (0.08 in/s), Flat Spec
9 dmВі/min to 162 000 mВі/h (2.5 gal/min to 100 000 gal/min)
Max. process pressurePN 40, Class 300, 20K
Medium temperature rangeLiner material hard rubber: 0 to +80 В°C (+32 to +176 В°F)
Liner material polyurethane: 20 to +50 В°C (4 to +122 В°F)
Flange material carbon steel: 10 to +60 В°C (+14 to +140 В°F)
Flange material stainless steel: 40 to +60 В°C (40 to +140 В°F)
DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 25 to 2400 (1 to 90"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protectionCompact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Status input
4-20 mA input
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power supplyDC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, UK Ex
Product safetyCE, C-tick, EAC marking
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
LR approval, DNV GL approval, ABS approval, BV approval
Pressure approvals and certificatesCRN
Material certificates3.1 material
Hygienic approvals and certificatesACS, KTW/W270, NSF 61, WRAS BS 6920
Comments