Endress+Hauser Proline Promass F 100
Coriolis flowmeter
- Overview +
- Comments +
Promass f 100 catalog:
- 8F1B25, DN25 1"
- 8F1B40, DN40 1 1/2"
- 8F1B15, DN15 1/2"
- 8F1B50, DN50 2"
- 8F1B08, DN08 3/8"
- 8F1B1F, DN150 6"
- 8F1B1H, DN100 4"
- 8F1B80, DN80 3"
- 8F1B2F, DN250 10"
Promass f 100 is a flowmeter with premium accuracy, robustness and an ultra-compact transmitter.
Measuring principle
Coriolis
Product headline
Flowmeter with premium accuracy, robustness and an ultra-compact transmitter.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measurement error В±0.05 % (PremiumCal). Medium temperature up to +240 В°C (+464 В°F). Nominal diameter: DN 8 to 250 (ВівЃ„в‚€ to 10").
Transmitter features
Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range
DN 8 to 250 (в…њ to 10")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume, flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)
Ambient temperature range
Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304), 1.4404 (316L)
Degree of protection
Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation
4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-Tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Marine approvals and certificates
ABS (American Bureau of Shipping)
BV (Bureau Veritas)
LR (Lloyds Register)
BV approval
CCS approval
Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Measuring principle
Coriolis
Product headline
Flowmeter with premium accuracy, robustness and an ultra-compact transmitter.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measurement error В±0.05 % (PremiumCal). Medium temperature up to +240 В°C (+464 В°F). Nominal diameter: DN 8 to 250 (ВівЃ„в‚€ to 10").
Transmitter features
Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range
DN 8 to 250 (в…њ to 10")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume, flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)
Ambient temperature range
Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304), 1.4404 (316L)
Degree of protection
Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation
4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-Tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Marine approvals and certificates
ABS (American Bureau of Shipping)
BV (Bureau Veritas)
LR (Lloyds Register)
BV approval, CCS approval
Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Measuring principle
Coriolis
Product headline
Flowmeter with premium accuracy, robustness and an ultra-compact transmitter.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measurement error В±0.05 % (PremiumCal). Medium temperature up to +240 В°C (+464 В°F). Nominal diameter: DN 8 to 250 (ВівЃ„в‚€ to 10").
Transmitter features
Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range
DN 8 to 250 (в…њ to 10")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume, flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)
Ambient temperature range
Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304), 1.4404 (316L)
Degree of protection
Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation
No local operation
Configuration via web browser and operating tools possible
Outputs
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-Tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Marine approvals and certificates
ABS (American Bureau of Shipping)
BV (Bureau Veritas)
LR (Lloyds Register)
BV approval
CCS approval
Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Measuring principle
Coriolis
Product headline
Flowmeter with premium accuracy, robustness and an ultra-compact transmitter.
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measurement error В±0.05 % (PremiumCal). Medium temperature up to +240 В°C (+464 В°F). Nominal diameter: DN 8 to 250 (ВівЃ„в‚€ to 10").
Transmitter features
Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range
DN 8 to 250 (в…њ to 10")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume, flow, reference density, concentration
Max. measurement error
Mass flow (liquid): В±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)
Ambient temperature range
Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304), 1.4404 (316L)
Degree of protection
Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation
4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-Tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Marine approvals and certificates
ABS (American Bureau of Shipping)
BV (Bureau Veritas)
LR (Lloyds Register)
BV approval
CCS approval
Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Endress Hauser Promass 100 Ordering Codes:
- 8F1B08-AADNBCISAAASC+AA
- 8F1B08-AADRABPHAABCB+AA
- 8F1B08-AADLACISAABSA+AA
- 8F1B15-AADMACISACWSD+AA
- 8F1B15-AADLABDSAAASB+AA
- 8F1B15-AADNBAPSAABSD+AA
- 8F1B25-AADMACISAD2NK+AA
- 8F1B25-AADLACISAABSM+AA
- 8F1B25-AADNBBNSAAASA+AA
- 8F1B40-AADNBCISAABSD+AA
- 8F1B40-AADLBAAHAABCM+AA
- 8F1B40-AADMAADSAD2SB+AA
- 8F1B50-AADMAALSAABSD+AA
- 8F1B50-AADNBAQSAAASK+AA
- 8F1B50-AADBACISAABSA+AA
- 8F1B80-AADNBAPHAADCK+AA
- 8F1B80-AADMAADSAABSL+AA
- 8F1B80-AADRBAQSAD2SB+AA
Buy Endress+Hauser Proline Promass F 100 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a world-known industrial automation supplier. In our catalog, you can find over 3 million products. We provide delivery worldwide cooperating with the best logistics companies. We offer you highly competitive prices for all items from our catalog. We give our customers delayed payments and better conditions when long-term cooperation. We are a stable and reliable company which has earned the trust of many customers, as can be seen from our client list.
Comments