Endress+Hauser Proline Promass F 200
Coriolis flowmeter
Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 % Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature rangeStandard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)
PN 100, Class 600, 63K
Wetted materialsMeasuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
- Overview
- Comments
Robust flowmeter with genuine loop-powered technology.
Measuring principleCoriolis
Product headlineRobust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications.
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measured error В±0.1 %. Medium temperature up to +205 В°C (+401 В°F). Nominal diameter: DN 8 to 80 (ВівЃ„в‚€ to 3").
Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
DN 8 to 80 (в…њ to 3")
Wetted materialsMeasuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement errorMass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 % Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressurePN 100, Class 600, 63K
Medium temperature rangeStandard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)
40 to +60 В°C (40 to +140 В°F)
Sensor housing material1.4301/1.4307 (304L), corrosion resistant
Transmitter housing materialAlSi10Mg, coated, 1.4404 (316L)
Degree of protectionIP66/67, type 4X enclosure
Display/Operation4...line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available
4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)
None
Digital communicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 18 to 35 V (4...20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4...20 mA)
DC 9 to 32 V (PROFIBUS PA)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product safetyCE, C-Tick, EAC marking
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
PED, CRN, AD 2000
Material certificates3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
3-A, EHEDG, cGMP
Measuring principleCoriolis
Product headlineRobust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications.
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measured error В±0.1 %. Medium temperature up to +205 В°C (+401 В°F). Nominal diameter: DN 8 to 80 (ВівЃ„в‚€ to 3").
Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
DN 8 to 80 (в…њ to 3")
Wetted materialsMeasuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement errorMass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 % Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressurePN 100, Class 600, 63K
Medium temperature rangeStandard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)
40 to +60 В°C (40 to +140 В°F)
Sensor housing material1.4301/1.4307 (304L), corrosion resistant
Transmitter housing materialAlSi10Mg, coated, 1.4404 (316L)
Degree of protectionIP66/67, type 4X enclosure
Display/Operation4...line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available
4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)
None
Digital communicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 18 to 35 V (4...20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4...20 mA)
DC 9 to 32 V (PROFIBUS PA)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product safetyCE, C-TICK
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
PED, CRN, AD 2000
Material certificates3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
3-A, EHEDG, cGMP
Measuring principleCoriolis
Product headlineRobust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications.
Highest process safety immune to fluctuating and harsh environments. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Mass flow: measured error В±0.1 %. Medium temperature up to +205 В°C (+401 В°F). Nominal diameter: DN 8 to 80 (ВівЃ„в‚€ to 3").
Convenient device wiring separate connection compartment. Safe operation no need to open the device due to display with touch control, background lighting. Integrated verification Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
DN 8 to 80 (в…њ to 3")
Wetted materialsMeasuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement errorMass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 % Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressurePN 100, Class 600, 63K
Medium temperature rangeStandard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)
40 to +60 В°C (40 to +140 В°F)
Sensor housing material1.4301/1.4307 (304L), corrosion resistant
Transmitter housing materialAlSi10Mg, coated, 1.4404 (316L)
Degree of protectionIP66/67, type 4X enclosure
Display/Operation4...line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
4...20 mA HART (passive)
4...20 mA (passive)
Pulse/frequency/switch output (passive)
None
Digital communicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 18 to 35 V (4...20 mA HART with/without pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4...20 mA)
DC 9 to 32 V (PROFIBUS PA)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product safetyCE, C-TICK
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
PED, CRN, AD 2000
Material certificates3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
3-A, EHEDG, cGMP
Comments
No comments yet