Endress+Hauser Proline Promass H 100
Coriolis flowmeter

Endress+Hauser Proline Promass H 100
We ship to United States of America!
Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas, Tantalum only): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Item Number: Proline Promass H 100
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

The chemically resistant single-tube flowmeter with an ultra-compact transmitter.

Measuring principle

Coriolis

Product headline

Chemically resistant single-tube flowmeter with an ultra-compact transmitter.
Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance.

Sensor features

Maximum safety for chemically aggressive fluids corrosion...resistant wetted parts. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (ВівЃ„в‚€ to 2"). Medium temperature up to +205 В°C (+401 В°F).

Transmitter features

Space-saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

DN 8 to 50 (ВівЃ„в‚€ to 2")

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas, Tantalum only): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Ambient temperature range

Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304)

Degree of protection

Standard: IP66/67, type 4X enclosure
Option: IP69

Display/Operation

4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible

Outputs

4...20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI

Product safety

CE, C-Tick, EAC marking

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for traceable verification cording to ISO 9001:2008 Section 7.6a (TГњV SГњD attestation)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material

Measuring principle

Coriolis

Product headline

Chemically resistant single-tube flowmeter with an ultra-compact transmitter.
Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance.

Sensor features

Maximum safety for chemically aggressive fluids corrosion...resistant wetted parts. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (ВівЃ„в‚€ to 2"). Medium temperature up to +205 В°C (+401 В°F).

Transmitter features

Space-saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

DN 8 to 50 (ВівЃ„в‚€ to 2")

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas, Tantalum only): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Ambient temperature range

Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304)

Degree of protection

Standard: IP66/67, type 4X enclosure
Option: IP69

Display/Operation

4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible

Outputs

4...20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety

CE, C-Tick, EAC marking

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for traceable verification cording to ISO 9001:2008 Section 7.6a (TГњV SГњD attestation)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material

Measuring principle

Coriolis

Product headline

Chemically resistant single-tube flowmeter with an ultra-compact transmitter.
Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance.

Sensor features

Maximum safety for chemically aggressive fluids corrosion...resistant wetted parts. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (ВівЃ„в‚€ to 2"). Medium temperature up to +205 В°C (+401 В°F).

Transmitter features

Space-saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

DN 8 to 50 (ВівЃ„в‚€ to 2")

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Measured variables

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas, Tantalum only): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Ambient temperature range

Standard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)

Sensor housing material

1.4301 (304), corrosion resistant

Transmitter housing material

Compact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304)

Degree of protection

Standard: IP66/67, type 4X enclosure
Option: IP69

Display/Operation

4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible

Outputs

4...20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

None

Digital communication

HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety

CE, C-Tick, EAC marking

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for traceable verification cording to ISO 9001:2008 Section 7.6a (TГњV SГњD attestation)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material


Buy Endress+Hauser Proline Promass H 100 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is an online electrical distributor. Here you can find any spare part you need. All your items can be combined and sent in one delivery. Prices and delivery conditions are our main focus. We provide free delivery for our regular customers. Our services will save you time and money which on the other side will help you grow your business!

Comments

No comments yet

Write a comment