Endress+Hauser Proline Promass K 10
Coriolis flowmeter
- Overview +
- Comments +
Promass k 10 catalog:
- 8KBB80, DN80 3"
- 8KBB50, DN50 2"
- 8KBB40, DN40 1 1/2"
- 8KBB25, DN25 1"
- 8KBB15, DN15 1/2"
- 8KBB08, DN08 3/8"
Flowmeter with minimized total cost of ownership with easy-to-use operation concept.
Measuring principle
Coriolis
Product headline
Flowmeter with minimized total cost of ownership with easy-to-use operation concept.
Measurement of liquids and gases in utility processes and basic applications.
Sensor features
Cost-effective general-purpose device alternative to mechanical flowmeters. Fewer process measuring points multivariable measurement (flow, density, temperature). Space-saving installation no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 В°C (+302 В°F). Process pressure up to 100 bar (1450 psi).
Transmitter features
Optimum usability operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning guided parameterization in advance and in the field. Integrated verification Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.
Nominal diameter range
DN 8 to 80 (в…њ to 3")
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables
Mass flow, temperature, Density (option), volume flow, corrected volume flow
Max. measurement error
Mass flow (liquid): В±0.5 % (standard), В±0.15 % (option)
Mass flow (gas): В±1 %
Measuring range
0 to 180 000 kg/h (0 to 6615 lb/min)
Max. process pressure
PN 40, Class 300, 40K
Medium temperature range
40 to +150 В°C (40 to +302 В°F)
Ambient temperature range
Standard: 20 to +60 В°C (4 to +140 В°F)
Sensor housing material
Stainless steel 1.4301 (304)
Transmitter housing material
AlSi10Mg, coated
Degree of protection
Standard: IP66/67, Type 4X enclosure
Display/Operation
2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
Digital communication
HART, MODBUS RS485
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX
IECEx
cCSAus
EAC
NEPSI
INMETRO
JPN
Uk Ex
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Pressure approvals and certificates
CRN, PED
Material certificates
3.1 material
Hygienic approvals and certificates
EC 1935, FDA, GB4806, cGMP
Measuring principle
Coriolis
Product headline
Flowmeter with minimized total cost of ownership with easy-to-use operation concept.
Measurement of liquids and gases in utility processes and basic applications.
Sensor features
Cost-effective general-purpose device alternative to mechanical flowmeters. Fewer process measuring points multivariable measurement (flow, density, temperature). Space-saving installation no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 В°C (+302 В°F). Process pressure up to 100 bar (1450 psi).
Transmitter features
Optimum usability operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning guided parameterization in advance and in the field. Integrated verification Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.
Nominal diameter range
DN 8 to 80 (в…њ to 3")
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables
Mass flow, temperature, Density (option), volume flow, corrected volume flow
Max. measurement error
Mass flow (liquid): В±0.5 % (standard), В±0.15 % (option)
Mass flow (gas): В±1 %
Measuring range
0 to 180 000 kg/h (0 to 6615 lb/min)
Max. process pressure
PN 40, Class 300, 40K
Medium temperature range
40 to +150 В°C (40 to +302 В°F)
Ambient temperature range
Standard: 20 to +60 В°C (4 to +140 В°F)
Sensor housing material
Stainless steel 1.4301 (304)
Transmitter housing material
AlSi10Mg, coated
Degree of protection
Standard: IP66/67, Type 4X enclosure
Display/Operation
2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
Digital communication
HART, MODBUS RS485
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX
IECEx
cCSAus
EAC
NEPSI
INMETRO
JPN
UK Ex
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
Pressure approvals and certificates
CRN, PED
Material certificates
3.1 material
Hygienic approvals and certificates
EC 1935, FDA, GB4806, cGMP
Promass K 10 Ordering Codes:
- 8KBB08-AAEMJDASAAASGA1+AA
- 8KBB08-AAMBHGDSAABSGA1+AA
- 8KBB08-AADMKDBSAFMWGA1+AA
- 8KBB15-AADMJDDSAD2SGA1+AA
- 8KBB15-AAEMADCSAD2SOA1+AA
- 8KBB15-AAEBHGCSAAASFA1+AA
- 8KBB25-AAMMJACSAD2SGA1+AA
- 8KBB25-AAEBHDBSAD2SGA1+AA
- 8KBB25-AAAFJGISAFTSGA1+AA
- 8KBB40-AAAFJDISAABSFA1+AA
- 8KBB40-AAEMHDABBFTSOA1+AA
- 8KBB40-AAMBAACSAAASFA1+AA
- 8KBB50-AAMBJGCSAFMWFA1+AA
- 8KBB50-AAEBKGBBBFTSGA1+AA
- 8KBB50-AADMADBSAABSOA1+AA
- 8KBB80-AADMJDCSAD2SFA1+AA
- 8KBB80-AAEBHGCBBFTSGA1+AA
- 8KBB80-AAMBAABSAAASOA1+AA
Buy Endress+Hauser Proline Promass K 10 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a fast-developing company supplying industrial automation components. You can get a wide variety of brands in one place. We ship to any location in the world. We will give you a good price offer. We provide the best level of technical support. Our service team will solve your problems in the best way.
Comments
No comments yet