Endress+Hauser Proline Promass S 100
Coriolis flowmeter
Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature range50 to +150 В°C (58 to +302 В°F)
Max. process pressurePN 40, Class 150, 20K
Wetted materialsMeasuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
- Overview
- Comments
Easy-to-clean flowmeter with self-drainable single-tube system and an ultra-compact transmitter.
Measuring principleCoriolis
Product headlineEasy-to-clean flowmeter with self-drainable single-tube system and an ultra-compact transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Increased process safety easily cleanable and fully self-drainable tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
DN 8 to 50 (в…њ to 2")
Wetted materialsMeasuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement errorMass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressurePN 40, Class 150, 20K
Medium temperature range50 to +150 В°C (58 to +302 В°F)
Ambient temperature rangeStandard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
1.4301 (304), corrosion resistant
Transmitter housing materialCompact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304)
Standard: IP66/67, type 4X enclosure
Option: IP69
4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
None
Digital communicationHART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supplyDC 20 to 30 V
Hazardous area approvalsATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safetyCE, C-Tick, EAC marking
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
PED, CRN
Material certificates3.1 material
Hygienic approvals and certificates3...A, EHEDG, cGMP
Measuring principleCoriolis
Hygienic approvals and certificatescGMP
Measuring principleCoriolis
Product headlineEasy-to-clean flowmeter with self-drainable single-tube system and an ultra-compact transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Increased process safety easily cleanable and fully self-drainable tube design. Fewer process measuring points multivariable measurement (flow, density, temperature). Space...saving installation no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Space...saving transmitter full functionality on the smallest footprint. Time...saving local operation without additional software and hardware integrated web server. Integrated verification Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
DN 8 to 50 (в…њ to 2")
Wetted materialsMeasuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement errorMass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressurePN 40, Class 150, 20K
Medium temperature range50 to +150 В°C (58 to +302 В°F)
Ambient temperature rangeStandard: 40 to +60 В°C (40 to +140 В°F)
Option: 50 to +60 В°C (58 to +140 В°F)
1.4301 (304), corrosion resistant
Transmitter housing materialCompact: AlSi10Mg, coated
Compact/ultra...compact: 1.4301 (304)
Standard: IP66/67, type 4X enclosure
Option: IP69
4...line backlit display available (no local operation)
Configuration via web browser and operating tools possible
4...20 mA HART (active)
Pulse/frequency/switch output (passive)
None
Digital communicationHART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supplyDC 20 to 30 V
Hazardous area approvalsATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safetyCE, C-Tick, EAC marking
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 Section 7.1.5.2 a (TГњV SГњD attestation)
PED, CRN
Material certificates3.1 material
Hygienic approvals and certificates3...A, EHEDG, cGMP
Comments